Effectiveness of clinical ultrasound parameters on changing intramuscular temperature.

نویسندگان

  • Timothy J Demchak
  • Marcus B Stone
چکیده

CONTEXT Researchers have recommended certain ultrasound treatment parameters for deep heating; however, we observed different parameters in the clinical setting. OBJECTIVE To compare the treatment effect of using observed clinical parameters (OCP) from 8 clinicians to the treatment effect of using the recommended parameters (RP) sited in research. DESIGN 2 x 2 repeated measures design. SETTING Sports injury research laboratory. PARTICIPANTS Ten healthy volunteers. INTERVENTIONS Two 1 MHz treatment, 1 RP treatment (1.5 W/cm2, 10-min, area-2 to 3 x ERA), and 1 OCP treatment (1.3 W/cm2, 8-min, area 3.9 X ERA). MAIN OUTCOME MEASURE Tricep surae temperature 3 cm below superficial tissue. RESULTS The RP treatment increase temperature from 36.4 +/- 1.0 to 40.3+/- 2.0 degrees C, which was a greater change than the OCP (36.5 +/- 1.2 to 38.2 +/- 1.6 degrees C). CONCLUSIONS The OCP treatment resulted in a lower heating affect than the RP. Small change in treatment area, intensity, and duration can have a large effect on temperature change.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effects of Intramuscular Electrical Stimulation on Clinical And Sonographic Parameters in Patient With Trigger Points: A Case Series Study

Objective: Myofascial pain syndrome is a common disorder with a prevalence of up to 85%. It is characterized by the presence of trigger points, which all people are commonly encountered at least once throughout their lifespan. Different physical therapy and medical treatments have used to manage myofascial pain syndrome. Intramuscular electrical stimulation intervention is a relatively new trea...

متن کامل

Effects of Ultrasound Working Parameters on the Ultrasonic Power Density Some Neglected Problems in the Application of Ultrasound Bath

Ultrasound has been widely employed in food industry, while some of its working parameters are usually neglected to be described in its application, which caused the difficulty of reproducing and comparing the results obtained by different groups. So it is definitely not sufficient to simply state the ultrasound conditions such as ultrasound power, frequency and t...

متن کامل

An Experimental Study on the Operating Parameters of Ultrasound-assisted Oxidative Desulfurization

In this research, the effects of important parameters, including the molar ratio of acetic acid to sulfur(S) , sonication time, temperature, and hydrogen the molar ratio of peroxide to sulfur on the performance of ultrasound-assisted oxidative desulfurization were studied using the response surface method (RSM). To this end, a model fuel containing n-decane and dibenzothiophene at a concentrati...

متن کامل

P-45: Predictive Value of Follicular Fluid VitaminD on Assisted Reproductive TechniqueOutcome

Background: Vitamin D, a steroid hormone, has critical roles in human health. The available data thus identify vitamin D as an important substance in processes involved in reproductive success and thereby suggest pathophysiological mechanisms for reproductive compromise in the setting of vitamin D deficiency. Realizing the prevalence of vitamin D insufficiency in our country, we hypothesized th...

متن کامل

A Comparison of Intramuscular Temperatures During 10-Minute 1.0-MHz Ultrasound Treatments at Different Intensities

Context: Research on therapeutic ultrasound has not focused on the duration needed to cause thermal change with various ultrasound intensities. Objective: To analyze triceps surae intramuscular temperature using 4 intensity levels after a 10-min 1-MHz continuous ultrasound treatment at a depth of 4 cm. Design: 1 4 repeated measures. Independent variable: intensity of 4 levels—0.5, 1.0, 1.5, and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of sport rehabilitation

دوره 17 3  شماره 

صفحات  -

تاریخ انتشار 2008