Effectiveness of clinical ultrasound parameters on changing intramuscular temperature.
نویسندگان
چکیده
CONTEXT Researchers have recommended certain ultrasound treatment parameters for deep heating; however, we observed different parameters in the clinical setting. OBJECTIVE To compare the treatment effect of using observed clinical parameters (OCP) from 8 clinicians to the treatment effect of using the recommended parameters (RP) sited in research. DESIGN 2 x 2 repeated measures design. SETTING Sports injury research laboratory. PARTICIPANTS Ten healthy volunteers. INTERVENTIONS Two 1 MHz treatment, 1 RP treatment (1.5 W/cm2, 10-min, area-2 to 3 x ERA), and 1 OCP treatment (1.3 W/cm2, 8-min, area 3.9 X ERA). MAIN OUTCOME MEASURE Tricep surae temperature 3 cm below superficial tissue. RESULTS The RP treatment increase temperature from 36.4 +/- 1.0 to 40.3+/- 2.0 degrees C, which was a greater change than the OCP (36.5 +/- 1.2 to 38.2 +/- 1.6 degrees C). CONCLUSIONS The OCP treatment resulted in a lower heating affect than the RP. Small change in treatment area, intensity, and duration can have a large effect on temperature change.
منابع مشابه
The Effects of Intramuscular Electrical Stimulation on Clinical And Sonographic Parameters in Patient With Trigger Points: A Case Series Study
Objective: Myofascial pain syndrome is a common disorder with a prevalence of up to 85%. It is characterized by the presence of trigger points, which all people are commonly encountered at least once throughout their lifespan. Different physical therapy and medical treatments have used to manage myofascial pain syndrome. Intramuscular electrical stimulation intervention is a relatively new trea...
متن کاملEffects of Ultrasound Working Parameters on the Ultrasonic Power Density Some Neglected Problems in the Application of Ultrasound Bath
Ultrasound has been widely employed in food industry, while some of its working parameters are usually neglected to be described in its application, which caused the difficulty of reproducing and comparing the results obtained by different groups. So it is definitely not sufficient to simply state the ultrasound conditions such as ultrasound power, frequency and t...
متن کاملAn Experimental Study on the Operating Parameters of Ultrasound-assisted Oxidative Desulfurization
In this research, the effects of important parameters, including the molar ratio of acetic acid to sulfur(S) , sonication time, temperature, and hydrogen the molar ratio of peroxide to sulfur on the performance of ultrasound-assisted oxidative desulfurization were studied using the response surface method (RSM). To this end, a model fuel containing n-decane and dibenzothiophene at a concentrati...
متن کاملP-45: Predictive Value of Follicular Fluid VitaminD on Assisted Reproductive TechniqueOutcome
Background: Vitamin D, a steroid hormone, has critical roles in human health. The available data thus identify vitamin D as an important substance in processes involved in reproductive success and thereby suggest pathophysiological mechanisms for reproductive compromise in the setting of vitamin D deficiency. Realizing the prevalence of vitamin D insufficiency in our country, we hypothesized th...
متن کاملA Comparison of Intramuscular Temperatures During 10-Minute 1.0-MHz Ultrasound Treatments at Different Intensities
Context: Research on therapeutic ultrasound has not focused on the duration needed to cause thermal change with various ultrasound intensities. Objective: To analyze triceps surae intramuscular temperature using 4 intensity levels after a 10-min 1-MHz continuous ultrasound treatment at a depth of 4 cm. Design: 1 4 repeated measures. Independent variable: intensity of 4 levels—0.5, 1.0, 1.5, and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of sport rehabilitation
دوره 17 3 شماره
صفحات -
تاریخ انتشار 2008