Pii: S0301-5629(01)00495-1
نویسندگان
چکیده
The limits and trade-offs of the axial resolution in elastography were investigated using a controlled simulation study. The axial resolution in elastography was estimated as the distance between the full widths at half-maximum of the strain profiles of two equally stiff lesions embedded in a softer homogeneous background. The results show that the upper bound of the axial resolution in elastography is controlled by the physical wave parameters of the ultrasound (US) system used to acquire the data (transducer center frequency and bandwidth). However, an inappropriate choice of the parameters used to process the US data (cross-correlation window length and shift between consecutive windows) may compromise the best resolution attainable. The measured elastographic axial resolution was found to be on the order of the ultrasonic wavelength. (E-mail: [email protected]) © 2002 World Federation for Ultrasound in Medicine & Biology.
منابع مشابه
Pii: S0301-5629(01)00472-0
The nonstationary variation in the noise performance of the cross-correlation-based strain estimator due to frequency-dependent attenuation and lateral and elevational signal decorrelation have been addressed theoretically in recent papers using the strain-filter approach. In this paper, we present the experimental verification and corroboration of the nonstationary effects on the strain estima...
متن کاملPii: S0301-5629(01)00478-1
In this paper we propose a novel feature-based contrast enhancement approach to enhance the quality of noisy ultrasound (US) images. Our approach uses a phase-based feature detection algorithm, followed by sparse surface interpolation and subsequent nonlinear postprocessing. We first exploited the intensity-invariant property of phase-based acoustic feature detection to select a set of relevant...
متن کاملPii: S0301-5629(01)00442-2
Elastic properties of tendon were assessed by two different approaches. Six fresh bovine Achilles tendon specimens were used. The first approach directly measured Young’s modulus along the transverse direction (Eperpendicular) and the longitudinal direction (Eparallel), using a cyclic compression–relaxation method. Young’s moduli were derived based on the measured strain and stress values. The ...
متن کاملPii: S0301-5629(01)00411-2
This study consisted of two parts. In the first part, the contrast-transfer efficiency (CTE) in elastography was extended to account for continuous changes of modulus distribution. It was shown that, for a finite size background, the strain contrast approaches the modulus contrast in the case of Gaussian distributions. Thus, an increase in the CTE was obtained. For a fixed background size, it w...
متن کاملPii: S0301-5629(01)00391-x
The use of liquid brominated hydrocarbons to form a planar reflecting interface with water is described. Gravity-based planar reflecting surfaces with known reflection coefficients can be used in system characterization for quantitative ultrasonics, and a set of surfaces with a range of reflection coefficients allows calibration of the output power and receiver gain of ultrasonic imaging system...
متن کامل