Quantifying thumb opposition kinematics using dynamic computed tomography.

نویسندگان

  • F D Kerkhof
  • E Brugman
  • P D'Agostino
  • B Dourthe
  • G H van Lenthe
  • F Stockmans
  • I Jonkers
  • E E Vereecke
چکیده

Current motion capture techniques all have shortcomings when applied to the 3D quantitative evaluation of thumb base motion. Dynamic CT might overcome these shortcomings but, so far, robustness of this technique in more than one specimen has not yet been demonstrated. The aim of the current study is to further evaluate the use of dynamic CT for quantification of thumb motion in a larger cadaveric study using a protocol which is feasible in a clinical context. A dynamic CT scan was acquired from six cadaveric human forearms, while a motion simulator imposed thumb opposition. After image acquisition and segmentation, carpal bone motion was quantified using helical axes. To enable comparisons between specimens, intersection points of the instantaneous helical axis with an anatomically defined plane were determined. Precision of the dynamic CT method, measured as variation in distances between silicon nitride beads between frames of a dynamic scan, was 0.43mm (+/-0.09mm) when fixed to the skin and 0.13mm (+/-0.04mm) when embedded into the bone. Absolute deviation between known and measured distances were not larger than 0.34mm. We could demonstrate and quantify that thumb opposition is associated with motion at the trapeziometacarpal and scaphotrapezotrapezoidal joints. High consistency in motion patterns between specimen were found, while the radiation dose was limited. We conclude that dynamic CT can be used to visualize and quantify 3D thumb kinematics, making it a promising method to explore kinematics in vivo.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Kinematics of Thumb Opposition

INTRODUCTION One of the most important hand functions is thumb opposition, which results from flexion, abduction and axial rotation at the carpometacarpal, metacarpophalangeal and interphalangeal joints [1]. The thenar muscles, innervated by the median nerve, are critical for coordinated thumb movements. It is commonly observed that thumb opposition is impaired with median neuropathy [2]. The c...

متن کامل

In vivo pilot study evaluating the thumb carpometacarpal joint during circumduction.

BACKGROUND Analysis of arthrokinematics may have clinical use in the diagnosis of dynamic instability of the thumb and wrist. Recent technological advances allow noninvasive, high-resolution imaging of skeletal (thumb and carpal bones) structures during motion. QUESTIONS/PURPOSES The primary purpose of this study is to define the arthrokinematics, estimated joint contact patterns, and distrib...

متن کامل

Four-Dimensional (4D) Printing: A New Evolution in Computed Tomography-Guided Stereolithographic Modeling. Principles and Application.

BACKGROUND Over the last decade, image-guided production of three-dimensional (3D) haptic biomodels, or rapid prototyping (RP), has transformed the way surgeons conduct preoperative planning. In contrast to earlier RP techniques such as stereolithography, 3D printing has introduced fast, affordable office-based manufacturing. We introduce the concept of 4D printing for the first time by introdu...

متن کامل

In Vivo Analysis of Trapeziometacarpal Joint Kinematics during Pinch Tasks

This study investigated how the posture of the thumb while performing common pinch movements and the levels of pinch force applied by the thumb affect the arthrokinematics of the trapeziometacarpal joint in vivo. Fifteen subjects performed the pinch tasks at the distal phalange (DP), proximal interphalangeal (PIP) joint, and metacarpophalangeal (MP) joint of the index finger with 0%, 50%, and 8...

متن کامل

Dynamic in vivo glenohumeral kinematics during scapular plane abduction in healthy shoulders.

STUDY DESIGN Controlled laboratory study. OBJECTIVES To measure superior/inferior translation and external rotation of the humerus relative to the scapula during scapular plane abduction using 3-D/2-D model image registration techniques. BACKGROUND Kinematic changes in the glenohumeral joint, including excessive superior translation of the humeral head and inadequate external rotation of th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 49 9  شماره 

صفحات  -

تاریخ انتشار 2016