Axillary vein puncture without contrast venography for pacemaker and defibrillator leads implantation.

نویسندگان

  • Dante Antonelli
  • Alexander Feldman
  • Nahum A Freedberg
  • Yoav Turgeman
چکیده

BACKGROUND Axillary vein puncture has been demonstrated to be an effective method for pacemaker and defibrillator leads implantation, without the complications encountered with the standard intrathoracic approach. OBJECTIVE Different techniques have been adopted for the cannulation of the axillary vein. We report our experience using the outer edge of the first rib below the inferior border of the clavicle as fluoroscopic landmark. METHOD A subcutaneous pocket is created 1-cm medially and parallel to the delto-pectoral groove and 2 cm below the clavicle. An 18-gauge needle from the upper border of the pocket is directed perpendicularly to the outer edge of the first rib just below the inferior border of the clavicle. If the vein is not entered, the needle is withdrawn and the puncture is repeated with slight variations of needle direction for a maximum of four to five times, then contrast-guided vein puncture is performed. Upon successful vein puncture, a guidewire is inserted and positioned in the superior vena cava. The remainder of the implantation is carried out in a routine manner. RESULTS The axillary vein was successfully cannulated without venography in 172 of 182 consecutive patients (94.5%); the vein could not be found in 10 patients (5.5%): in these patients the vein was successfully cannulated after venography performance. No pneumothorax, hemothorax, or brachial plexus injury occurred. CONCLUSIONS Our approach of axillary venipunture using fluoroscopic landmark, without contrast venography, is simple, safe, and effective.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator lead implantation.

AIMS Contrast-guided axillary vein puncture is commonly used for pacemaker or defibrillator lead implantation. Venous spasm during contrast-guided axillary vein puncture has been reported rarely. We investigated the incidence of venous spasm during contrast-guided axillary vein puncture and the impact of venous spasm on axillary vein puncture. METHODS AND RESULTS Seventy-four consecutive pati...

متن کامل

A safe and effective method for pacemaker implantation in children Axillary vein puncture for device implantation and use of 4F catheter- delivered pacing leads in children

Background: Contrast-guided axillary vein puncture has gained popularity for pacemaker and implantable cardioverter defibrillator (ICD) implantation in adults owing to its low risk profile, and could be an alternative to subclavian vein puncture, which is commonly performed in children. The Medtronic 3830 lead is a 4.1F lumenless catheter-delivered lead which may be particularly well-suited for...

متن کامل

Venous spasm during pacemaker implantation.

A 75-years-old female presented with dyspnea and syncope. Electrocardiogram revealed atrial fibrillation and complete atrioventricular block. She was therefore listed for pacemaker implantation on the next day. Initial attempt at venous access was left axillary vein. A venogram showed good venous anatomy (Fig. 1a). Several attempts to puncture axillary vein were made. However, there was no good...

متن کامل

Incidence of venous obstruction following insertion of an implantable cardioverter defibrillator. A study of systematic contrast venography on patients presenting for their first elective ICD generator replacement.

AIMS The number of implantable cardioverter defibrillator (ICD) implantations, as well as follow-up procedures such as generator exchanges, lead revisions and lead system upgrades, is ever-increasing. Lead revisions and implantation of additional leads require venous access at the site of the previous ICD implantation. The aim of our study was therefore to evaluate the incidence of venous obstr...

متن کامل

Hemoptysis After Subclavian Vein Puncture for Pacemaker Implantation: Importance of Wire-Guided Venous Puncture

We report a case of hemoptysis occurring after subclavian vein puncture for pacemaker implantation. Hemoptysis related to injury of lung parenchyma is a rare complication of subclavian vein access and is usually self limited, but can affect prognosis in critically ill patients. Venogram-guided or even better wire-guided venous puncture allow safe access to the subclavian vein in difficult cases...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 36 9  شماره 

صفحات  -

تاریخ انتشار 2013