Improved Image Fusion in PET/CT Using Hybrid Image Reconstruction and Super-Resolution

نویسندگان

  • John A. Kennedy
  • Ora Israel
  • Alex Frenkel
  • Rachel Bar-Shalom
  • Haim Azhari
چکیده

PURPOSE To provide PET/CT image fusion with an improved PET resolution and better contrast ratios than standard reconstructions. METHOD Using a super-resolution algorithm, several PET acquisitions were combined to improve the resolution. In addition, functional PET data was smoothed with a hybrid computed tomography algorithm (HCT), in which anatomical edge information taken from the CT was employed to retain sharper edges. The combined HCT and super-resolution technique were evaluated in phantom and patient studies using a clinical PET scanner. RESULTS In the phantom studies, 3 mm(18)F-FDG sources were resolved. PET contrast ratios improved (average: 54%, range: 45%-69%) relative to the standard reconstructions. In the patient study, target-to-background ratios also improved (average: 34%, range: 17%-47%). Given corresponding anatomical borders, sharper edges were depicted. CONCLUSION A new method incorporating super-resolution and HCT for fusing PET and CT images has been developed and shown to provide higher-resolution metabolic images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

What does decreased funding for science mean to the United States?

Purpose. To provide PET/CT image fusion with an improved PET resolution and better contrast ratios than standard reconstructions.Method. Using a super-resolution algorithm, several PET acquisitions were combined to improve the resolution. In addition, functional PET data was smoothed with a hybrid computed tomography algorithm (HCT), in which anatomical edge information taken from the CT was em...

متن کامل

Small-animal imaging using clinical positron emission tomography/computed tomography and super-resolution.

Considering the high cost of dedicated small-animal positron emission tomography/computed tomography (PET/CT), an acceptable alternative in many situations might be clinical PET/CT. However, spatial resolution and image quality are of concern. The utility of clinical PET/CT for small-animal research and image quality improvements from super-resolution (spatial subsampling) were investigated. Na...

متن کامل

Effect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET

Objective(s): In order to evaluate the effect of post-reconstruction Gaussian filtering on image quality and myocardial blood flow (MBF) measurement by dynamic N-13 ammonia positron emission tomography (PET), we compared various reconstruction and filtering methods with image characteristics. Methods: Dynamic PET images of three patients with coronary artery disease (male-female ratio of 2:1; a...

متن کامل

Improving Super-resolution Techniques via Employing Blurriness Information of the Image

Super-resolution (SR) is a technique that produces a high resolution (HR) image via employing a number of low resolution (LR) images from the same scene. One of the degradations that attenuates performance of the SR is the blurriness of the input LR images. In many previous works in the SR, the blurriness of the LR images is assumed to be due to the integral effect of the image sensor of the im...

متن کامل

Methods to evaluate the performance of kilovoltage cone-beam computed tomography in the three-dimensional reconstruction space

Background: Cone-beam computed tomography (CBCT) scanners for image-guided radiotherapy are in clinical use today, but there has been no consensus on uniform acceptance to verify the CBCT image quality yet. The present work proposed new methods to fully evaluate the performance of CBCT in its three-dimensional (3D) reconstruction space. Materials and Methods: Compared to the traditional methods...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International Journal of Biomedical Imaging

دوره 2007  شماره 

صفحات  -

تاریخ انتشار 2007