Increasing the energy dynamic range of solid-state nuclear track detectors using multiple surfaces.

نویسندگان

  • A B Zylstra
  • H G Rinderknecht
  • N Sinenian
  • M J Rosenberg
  • M Manuel
  • F H Séguin
  • D T Casey
  • J A Frenje
  • C K Li
  • R D Petrasso
چکیده

Solid-state nuclear track detectors, such as CR-39, are widely used in physics and in many inertial confinement fusion (ICF) experiments. In the ICF experiments, the particles of interest, such as D(3)He-protons, have ranges of order of the detector thickness. In this case, the dynamic range of the detector can be extended by recording data on both the front and back sides of the detector. Higher energy particles which are undetectable on the front surface can then be measured on the back of the detector. Studies of track formation under the conditions on the front and back of the detector reveal significant differences. Distinct front and back energy calibrations of CR-39 are therefore necessary and are presented for protons. Utilizing multiple surfaces with additional calibrations can extend the range of detectable energies on a single piece of CR-39 by up to 7-8 MeV. The track formation process is explored with a Monte Carlo code, which shows that the track formation difference between front and back is due to the non-uniform ion energy deposition in matter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of Contemporary and Retrospective Radon Concentration in Ramsar Dwellings Using Polycarbonate Detector

The origins of radon gas are the amount of uranium decay in the soil that is released into space and through the interior gaps of  buildings. Radon can enter the respiratory system and cause radiation hazards. Recently research has identified Radon as the second leading cause of lung cancer after cigarette smoking. The indoor concentration of Radon progeny is mentioned as an important issue reg...

متن کامل

Proton beam dosimetry by CR-39 track-etched detector

Background: High and intermediate energy protons are not able to form a track in a solid state nuclear track detector (SSNTD) directly. However, such tracks can be formed through secondary particles created during primary radiation nuclear reactions in a SSNTD. Materials and Methods: The protons with primary energies of 9.6 and 30 MeV available at the cyclotron accelerator with corresponding lo...

متن کامل

روش جدید خورش چندمرحله‌ای کالیبراسیون آشکارساز ردپای هسته‌ای 39CR- برای بیناب‌سنجی ذرات آلفا

In this paper, application of the CR-39 passive nuclear track detector for spectrometry of alpha particles is investigated. To this end, a standard Am-241 source as the alpha radiation source, and brass collimators with different heights for energy determination of alpha particles were utilized. The detectors were irradiated by alpha particles in the energy range of 0.8 to 4.8 MeV and then were...

متن کامل

Digital System to Characterize Solid State Nuclear Track Detectors

A digital system to characterize solid state nuclear track detectors(SSNTD) has been developed. It was used in the study of two detectors and its performance evaluated by comparing the obtained results with those determined by using an analog system, already in use for such purpose. The comparison of the results together with the feasibility and rapidness in data acquisition have demonstrated t...

متن کامل

مطالعه غلظت رادن‌ در محیط‌های مسکونی شهرستان طارم-زنجان

Background and Objective: Radon is highly regarded because of its impacts on public health. Northern regions of Iran have a high potential for radon emissions. This research aimed to measure residential radon concentrations in Tarom country- Zanjan and to compare the results with international standards and acceptable values. Materials and Methods: Passive diffusive samplers, Solid State Nuc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 82 8  شماره 

صفحات  -

تاریخ انتشار 2011