Sonographic and histological development of high-intensity focused ultrasound in rabbit muscle
نویسندگان
چکیده
The purpose of this study was to examine the development of the ultrasonic image and histology of rabbit leg muscles irradiated with high-intensity focused ultrasound (HIFU). HIFU was applied to muscles of 40 legs of 20 rabbits. The results of sonication were examined by ultrasound from 10 min to 28 days after HIFU radiation in 19 rabbits. Pathological examination was performed on Day 1 and Day 28. The echo of rabbit leg muscle was revealed to be homogeneous and hypoechoic, as detected by the two-dimensional ultrasound prior to HIFU radiation. The echo of the HIFU lesion was hyperechoic at 10 min after HIFU radiation. The echo at the central point of the HIFU lesion became lower 1 h after HIFU radiation, there was a distinct hyperechoic border zone surrounding the site of sonication. During Days 1-3, the echo of these sites became lower. One week later, there was a hypoechoic border zone surrounding the sites of sonication. Two to four weeks later, the volume of sonication lesions decreased gradually. The echo of sonication lesions was homogeneous and hypoechoic. On Day 1 after HIFU radiation, the HIFU lesion was best observed grossly as pale round areas and was surrounded by hyperemia. The pathology results demonstrated that the cytoplasm was red-stained, the karyon was clear, the muscle cells subjected to HIFU radiation appeared with cytoplasm condensation, and nuclear and cell membrane breakdown was present. Numerous leukocytes and lymphocytes were detected surrounding the coagulation necrosis lesions. Four weeks later, the HIFU lesion was observed as discrete, with sharp differentiation between normal and ablated tissue. The lesion was best observed grossly as pale-yellow round areas and without hyperemia. The leukocyte and lymphocyte infiltration was not apparent in or around the sonications. Fibroblast hyperplasia, fatty infiltration and small scar formation in and around the sonications were observed. Ultrasound examination plays an important role in visualization after HIFU radiation. It provides a basis for understanding ultrasonic image development in clinical applications such as the treatment of uterine fibroids.
منابع مشابه
Therapeutic effects of high intensity focused ultrasound for in patients with benign uterine tumors with regard to lifestyle and obstetric characteristics
Background: The present investigation compared the decrease in the volume of benign tumor before and after High Intensity Focused Ultrasound (HIFU) treatment to evaluate the therapeutic effects of HIFU. in terms of Lifestyle and obstetric characteristics of in patients with Benign Uterine Tumors. Materials and Methods: To collect the data on each patients’ lifestyle and obstetric characteristic...
متن کاملNumerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator
Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...
متن کاملLOW INTENSITY PULSED ULTRASOUND TREATMENT INCREASES RABBIT RADIAL FRACTURE HEALING
In order to study the effect of ultrasound (US) on bone healing, a complete transverse fracture was made in the right radius of adult male rabbits by a cutter. 52 rabbits were used: group I. control (n= 17): group 2. test (n:=: 15): group 3, intact (n= I) and group 4 (n= 12) who were examined only for evaluation of the cutter effects in detail. 7 animals were operated with a Gigli saw. The ...
متن کاملDestructive effect of HIFU on rabbit embedded endometrial carcinoma tissues and their vascularities
OBJECTIVES To evaluate damage effect of High-intensity focused ultrasound on early stage endometrial cancer tissues and their vascularities. MATERIALS AND METHODS Rabbit endometrial cancer models were established via tumor blocks implantation for a prospective control study. Ultrasonic ablation efficacy was evaluated by pathologic and imaging changes. The target lesions of experimental rabbit...
متن کاملThe Effects of Intramuscular Electrical Stimulation on Clinical And Sonographic Parameters in Patient With Trigger Points: A Case Series Study
Objective: Myofascial pain syndrome is a common disorder with a prevalence of up to 85%. It is characterized by the presence of trigger points, which all people are commonly encountered at least once throughout their lifespan. Different physical therapy and medical treatments have used to manage myofascial pain syndrome. Intramuscular electrical stimulation intervention is a relatively new trea...
متن کامل