Detection and Diagnosis of Compound Faults in a Reciprocating Compressor based on Motor Current Signatures
نویسندگان
چکیده
The University Repository is a digital collection of the research output of the University, available on Open Access. Copyright and Moral Rights for the items on this site are retained by the individual author and/or other copyright owners. Users may access full items free of charge; copies of full text items generally can be reproduced, displayed or performed and given to third parties in any format or medium for personal research or study, educational or not-for-profit purposes without prior permission or charge, provided:
منابع مشابه
Phase Compensation Based Dynamic Time Warping for Fault Diagnosis Using Motor Current Signal
Dynamic Time Warping (DTW) is a time domain based method and widely used in various similar recognition and data mining applications. This paper presents a phase compensation based DTW to process the motor current signals for detecting and quantifying various faults in a two-stage reciprocating compressor under different operating conditions. DTW is an effective method to align up two signals f...
متن کاملFault Diagnosis of Motor Drives Using Stator Current Signal Analysis Based on Dynamic Time Warping
Electrical motor stator current signals have been widely used to monitor the condition of induction machines and their downstream mechanical equipment. The key technique used for current signal analysis is based on Fourier transform (FT) to extract weak fault sideband components from signals predominated with supply frequency component and its higher order harmonics. However, the FT based metho...
متن کاملFUZZY BASED FAULT DETECTION AND CONTROL FOR 6/4 SWITCHED RELUCTANCE MOTOR
Prompt detection and diagnosis of faults in industrial systems areessential to minimize the production losses, increase the safety of the operatorand the equipment. Several techniques are available in the literature to achievethese objectives. This paper presents fuzzy based control and fault detection for a6/4 switched reluctance motor. The fuzzy logic control performs like a classicalproporti...
متن کاملVibration Analysis of an Air Compressor Based on a Hypocycloidal Mechanism: an Experimental Study
In this paper, the experimental vibration analysis of a single cylinder air compressor based on a hypocycloid straight line mechanism (HSM) is investigated. The HSM mechanism uses planetary gears to convert rotational motion to purely linear motion. In the conventional air compressor, the slider- crank mechanism is replaced by the HSM mechanism with appropriate counterweights. The constructed s...
متن کاملThe Detection of Liquid Slugging Phenomena in Reciprocating Compressors via Power Measurements
The presence of liquid refrigerant in the compressor cylinder during operation, or liquid slugging, is one of the most common causes of failure in reciprocating compressors. We propose to detect this fault by analyzing the electrical current flowing into the compressor and identifying the change in the load on the motor caused by the presence of liquid in the compressor cylinder. Two different ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2016