Determination of iron, manganese and zinc in water samples by flame atomic absorption spectrophotometry after preconcentration with solid-phase extraction onto Ambersorb 572.

نویسندگان

  • Erdal Kendüzler
  • A Rehber Türker
چکیده

A solid-phase extraction method for the preconcentration of Fe, Mn and Zn on a column containing Ambersorb 572 has been developed, and the determination of Fe, Mn and Zn in water using a flame atomic absorption spectrophotometer (FAAS) has been performed. The optimum preconcentration parameters of the procedure have been determined. The effect of the pH, complexing agent, amount of adsorbent, flow rate, concentration and volume of the elution solution and interfering ions on the recovery of the analytes were investigated. The recoveries of Fe, Mn and Zn were 99 +/- 3%, 98 +/- 3% and 99 +/- 3% at the 95% confidence level, respectively, under the optimum conditions. Fe, Mn and Zn were preconcentrated up to 50, 100, 200, respectively. The limits of detection of Fe, Mn and Zn are 2.5, 0.68 and 0.24 micrograms l-1, respectively. The adsorption capacity of the adsorbent was found to be 10.9, 13.1 and 21.5 mg g-1 for Fe, Mn and Zn, respectively. The method has been applied to the determination of these metal ions in tap-water and river-water samples. The precision and the accuracy of the method is very good. The relative standard deviation and the relative error are lower than 4%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sepration and determination trace amount of cadmium ions in real and water samples by cloud point extraction - flame atomic absorption spectrophotometry after preconcentration with non-ionic surfactant Triton-X114

2-(3- indolyl) – 4,5 di phynyl imidazole.(IDPI) was used as a complexing agent in cloud point extraction for the first time and applied for selective pre-concentration of trace amounts of cadmium. The method is based on the extraction of cadmium at pH= 7.0 by using non-ionic surfactant Triton-X114 and 2-(3- indolyl) – 4,5 di phynyl imidazole. (IDPI) as a chelating agent. The adopted concentrati...

متن کامل

Application of Sulfur Nanoparticles as a Solid Phase Extraction Sorbent for the Preconcentration of Lead(II) and Palladium(II) in Environmental Samples Prior to Flame Atomic Absorption Spectrometry Determination

The application of sulfur nanoparticles as an efficient adsorbent for the solid-phase extraction and determination of the trace amounts of Pb and Pd ions was investigated in environmental samples using flame atomic absorption spectrometry. Effects of various parameters such as pH, flow rate of sample and eluent, type and concentration of eluent, sample volume, amount of adsorbent and interferin...

متن کامل

Evaluation of two different extraction techniques on determination of 〖Pb〗^(+2) contents of wastes of dye manufacturing industries

Extraction of trace amounts of toxic heavy metals from complicated environmental matrixes is a  challenging task. The aim of this investigation is the comparison of the extraction efficiencies and other related experimental variables ( chemicals, effect of pH, potential interfering ions) on the determination of inorganic lead ( ) which is present in waste water of dye industries. Compared techn...

متن کامل

Determination of Iron Species by Combination of Solvent Assisted-Dispersive Solid Phase Extraction and Spectrophotometry

A simple, rapid and sensitive solvent assisted-dispersive solid phase extraction method was developed for the extraction of iron(II) prior to its spectrophotometric determination. The Fe(II) reacted with 2,4,6-tris(2-pyridyl)-1,3,5-triazine, neutralized with sodium dodecyl sulfate and extracted onto the fine particles of benzophenone which were formed upon rapid injection of a mixture of benzop...

متن کامل

Solid phase extraction of trace cobalt (II) in industrial wastewaters by modified nanotube carbon carboxyl and its determination with flame atomic spectroscopy

Applying a simple and selective sample preparation procedure prior to instrumental analysis is the most important and crucial step in an analytical process. Up to now, various sample preparation techniques based on solid phase extraction (SPE) systems have been developed to isolate various types of analytes from different matrices. In the method presented for preconcentration and measurement of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 18 8  شماره 

صفحات  -

تاریخ انتشار 2002