Validation of a model-based measurement of the minimum insert thickness of knee prostheses

نویسندگان

  • E. A. van IJsseldijk
  • M. K. Harman
  • J. Luetzner
  • E. R. Valstar
  • B. C. Stoel
  • R. G. H. H. Nelissen
  • B. L. Kaptein
چکیده

INTRODUCTION Wear of polyethylene inserts plays an important role in failure of total knee replacement and can be monitored in vivo by measuring the minimum joint space width in anteroposterior radiographs. The objective of this retrospective cross-sectional study was to compare the accuracy and precision of a new model-based method with the conventional method by analysing the difference between the minimum joint space width measurements and the actual thickness of retrieved polyethylene tibial inserts. METHOD Before revision, the minimum joint space width values and their locations on the insert were measured in 15 fully weight-bearing radiographs. These measurements were compared with the actual minimum thickness values and locations of the retrieved tibial inserts after revision. RESULTS The mean error in the model-based minimum joint space width measurement was significantly smaller than the conventional method for medial condyles (0.50 vs 0.94 mm, p < 0.01) and for lateral condyles (0.06 vs 0.34 mm, p = 0.02). The precision (standard deviation of the error) of the methods was similar (0.84 vs 0.79 mm medially and both 0.46 mm laterally). The distance between the true minimum joint space width locations and the locations from the model-based measurements was less than 10 mm in the medial direction in 12 cases and less in the lateral direction in 13 cases. CONCLUSION The model-based minimum joint space width measurement method is more accurate than the conventional measurement with the same precision. Cite this article: Bone Joint Res 2014;3:289-96.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of the in vivo volumetric wear measurement for total knee prostheses in model-based RSA.

Implant failure related to polyethylene wear remains an important issue in total knee arthroplasty. Polyethylene wear is usually assessed in vivo by measuring the remaining insert thickness on X-ray images of the knee. To reflect the amount of wear debris more accurately, a 3-dimensional overlap measurement has been suggested, which is based on implant component models which are matched on cali...

متن کامل

Investigating the Impact of Knee Prosthesis in Patients’ Body on Radiation Dose Distribution: A Monte Carlo Approach

Introduction: Metal prostheses in patients affect the radiotherapy dose distribution. Metal prostheses with high density and atomic number cause major changes in scattering and attenuation of radiation. The present study aims to assess the impact of metal knee prosthesis with various dimensions and materials on radiotherapy dose distribution. Material and Methods: In this research, the Varian L...

متن کامل

Histomorphometrical Changes on the Knee Joints of Male and Female Rats After Moderate Exercise Program

Introduction: Osteoarthritis (OA) is one of the most common joint diseases that is accompanied with cartilage loss and finally leads to joint destruction. The most common joint that is affected in OA is the knee joint. Knee joint OA may lead to significant illness.&nbsp; Methods: The effect of excessive running load on the development of knee OA was investigated in rats. This study aimed to ev...

متن کامل

Cross-Cultural Adaptation and Validation of the Persian Version of the Oxford Knee Score in Patients with Knee Osteoarthritis

Background: The Oxford Knee Score (OKS) is a short patient-reported outcome instrument that measures pain and physical activity related to knee osteoarthritis. The purpose of this study is to evaluate, construct validity and consistent reliability of the Persian version of the OKS.Methods: The case series consisted of 80 patients who were clinically diagnosed with having knee osteoarthritis. Al...

متن کامل

Anthropometric Measurements of Distal Femur to Design the Femoral Component of Total Knee Arthroplasty for the Iranian Population

Background: Acquiring knowledge about anatomic and geometric quantities of bones is among the most vitalparameters in orthopedic surgery that has a significant effect on the treatment of various disorders and subsequentoutcomes. The aim of this study was to obtain anthropometric information for distal femur in order to compare withsimilar dimensions of prosthesis used in total...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2014