A comparison of the temperature difference according to the placement of a nasopharyngeal temperature probe
نویسندگان
چکیده
BACKGROUND The purpose of this study was to compare temperatures measured at three different sites where a nasopharyngeal temperature probe is commonly placed. METHODS Eighty elective abdominal surgical patients were enrolled. After anesthesia induction, four temperature probes were placed at the nasal cavity, upper portion of the nasopharynx, oropharynx, and the esophagus. The placement of the nasopharyngeal temperature probes was evaluated using a flexible nasendoscope, and the depth from the nares was measured. The four temperatures were simultaneously recorded at 10-minute intervals for 60 minutes. RESULTS The average depths of the probes that were placed in the nasal cavity, upper nasopharynx, and the oropharynx were respectively 5.7 ± 0.9 cm, 9.9 ± 0.7 cm, and 13.6 ± 1.7 cm from the nares. In the baseline temperatures, the temperature differences were significantly greater in the nasal cavity 0.32 (95% CI; 0.27-0.37)℃ than in the nasopharynx 0.02 (0.01-0.04)℃, and oropharynx 0.02 (-0.01 to 0.05)℃ compared with the esophagus (P < 0.001). These differences were maintained for 60 minutes. Twenty patients showed a 0.5℃ or greater temperature difference between the nasal cavity and the esophagus, but no patient showed such a difference at the nasopharynx and oropharynx. CONCLUSIONS During general anesthesia, the temperatures measured at the upper nasopharynx and the oropharynx, but not the nasal cavity, reflected the core temperature. Therefore, the authors recommend that a probe should be placed at the nasopharynx (≈ 10 cm) or oropharynx (≈ 14 cm) with mucosal attachment for accurate core temperature measurement.
منابع مشابه
Evaluation of Suitable Connection Point of Skin Probe for Temperature Control in Premature Infants under Radiant Heating Admitted to Neonatal Intensive Care Unit
Background and Objectives: Placement of skin heat probe for continuous monitoring of infant body temperature is one of the main components of neonatal care. Therefore, managing the body temperature of newborns under radiation warmers requires a lot of attention from nurses to prevent unwanted complications. The aim of this study was to determine the appropriate connection point of skin probe fo...
متن کاملComparison sensitivity and specificity temporal artery temperature measurement with axillary and nasopharyngeal methods in adult
Aims: temporal artery thermometers (TAT) of new tools for measuring body temperature, few studies have been conducted to evaluate the accuracy and reliability of thermometers and is still uncertain accuracy and reliability this thermometers.This study to evaluate the accuracy of the two methods of measuring body temperature by the thermometer axillary and temporal artery compared with nas...
متن کاملDifference between efficiency of ultrasound treatments above and below the membrane surface in membrane clarification of pomegranate juice
Microfiltration can clarify pomegranate juice; however, fouling is a limiting phenomenon in the process. In current work ultrasound was applied above and below the membrane surface to reduce fouling after removing temperature effect. A hydrophilic mixed cellulose ester membrane with pore size of 0.45 μm was used in lab scale flat sheet module. Membrane module was placed above and below the ultr...
متن کاملDifference between efficiency of ultrasound treatments above and below the membrane surface in membrane clarification of pomegranate juice
Microfiltration can clarify pomegranate juice; however, fouling is a limiting phenomenon in the process. In current work ultrasound was applied above and below the membrane surface to reduce fouling after removing temperature effect. A hydrophilic mixed cellulose ester membrane with pore size of 0.45 μm was used in lab scale flat sheet module. Membrane module was placed above and below the ultr...
متن کاملفراوانی ویروسهای EBV و HPV در کارسینوم نازوفارنکس به روش هیبریداسیون درجا
Nasopharyngeal carcinoma, particulary tumors endemic to the Far East, commonly harbors Epstein-Barr virus. The detection of nuclear antigen associated with EBV and viral DNA in NPC cells have revealed that EBV can infect epithelial cells and is associated with transformation. Human papilloma virus is an epitheliotrophic oncogenic virus that has been detected in a variety of head and neck tu...
متن کامل