Off-site determinations of effective renal plasma flow using technetium-99m-MAG3 and single blood sampling.
نویسندگان
چکیده
UNLABELLED This study evaluated the feasibility of determining effective renal plasma flow (ERPF) at an off-site central laboratory by transferring blood samples from the on-site laboratory. METHODS Blood samples were obtained from 66 patients referred for renal imaging with 99mTc-MAG3. ERPF values were determined using the single blood sample method (BSM) at both on- and off-site laboratories. The ERPF values were classified clinically as normal or abnormal. Both the ERPF values and clinical classification were compared between on- and off-site laboratories. RESULTS The off-site ERPF overestimated those on-site by 2.8% (paired Student's t-test p < 10(-5)). However, off-site ERPF values highly correlated with the values obtained on-site (r = 0.99; p < 10(-5)). In addition, the clinical classification for each patient determined at each site was identical. CONCLUSION ERPF can be determined accurately off-site. This method should allow many nuclear medicine departments access to the ERPF determination by the BSM at a central off-site laboratory.
منابع مشابه
Derived GFR (dGFR) Values from Technetium-99m-MAG3 Data: A Comparison with the 24-Hour Creatinine Clearance
Objective: Glomerular filtration can eliminate a substance only from the filtered fraction of the renal plasma flow. Since that fraction normally is 20%, ERPF agents clear from the kidneys about five times as fast as GFR agents. In most chronic renal diseases, the filtration fraction (GFR divided by ERPF) is largely unaffected, so the GFR can be estimated by dividing the ERPF by five. The aim o...
متن کاملEvaluation of Renal Function: A Comparison Between Camera-Based Tc-99m MAG3 and 24-Hour Creatinine Clearances
OBJECTIVE: The 24-hour creatinine clearance is the standard clinical technique to measure renal function; however, this measurement is cumbersome and inconvenient for patients. We hypothesized that a camera-based Tc-99m mercaptoacetyltriglycine (MAG3) clearance obtained simultaneously with a standard MAG3 scan would correlate well with the 24-hour creatinine clearance and could serve as a simpl...
متن کاملComparison of Technetium-99m MAG3TM and lodine-131 OIH ERPF Results Using the Camera Technique
Recent studies have suggested that technetium-99m (19mTc) MAG3 can be substituted for iodine-131 ( 131 I) OIH, with better image quality and lower radiation dose. This study compares the two radiopharmaceuticals for effective renal plasma flow (ERPF) results using only the camera method. Twenty patients with varying degrees of renal impairment were studied. In 13 of these patients, direct compa...
متن کاملComparison of Technetium-99m MAG3TM and lodine-131 OIH ERPF Results Using the Camera Technique
Recent studies have suggested that technetium-99m (19mTc) MAG3 can be substituted for iodine-131 ( 131 I) OIH, with better image quality and lower radiation dose. This study compares the two radiopharmaceuticals for effective renal plasma flow (ERPF) results using only the camera method. Twenty patients with varying degrees of renal impairment were studied. In 13 of these patients, direct compa...
متن کاملAcetazolamide assisted Tc-99m MAG3 renography to assess renal blood flow reserve.
OBJECTIVE The present study examines whether or not baseline and acetazolamide (ACZ) Tc-99m MAG3 renography can assess renal blood flow reserve. METHODS Renography proceeded for 50 min after sequential injections of 370 MBq Tc-99m MAG3 for baseline renography and 10 min after a 1,000 mg injection of ACZ for ACZ renography. Effective renal plasma flow of renal cortex (cERPF) in each kidney and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine technology
دوره 26 1 شماره
صفحات -
تاریخ انتشار 1998