Reproducibility and feasibility of right ventricular strain and strain rate (SR) as determined by myocardial speckle tracking during high-intensity upright exercise: a comparison with tissue Doppler-derived strain and SR in healthy human hearts

نویسندگان

  • Rachel N Lord
  • Keith George
  • Helen Jones
  • John Somauroo
  • David Oxborough
چکیده

This study aimed to establish feasibility for myocardial speckle tracking (MST) and intra-observer reliability of both MST and tissue velocity imaging (TVI)-derived right ventricular (RV) strain (ϵ) and strain rate (SR) at rest and during upright incremental exercise. RV ϵ and SR were derived using both techniques in 19 healthy male participants. MST-derived ϵ and SR were feasible at rest (85% of segments tracked appropriately). Feasibility reduced significantly with progressive exercise intensity (3% of segments tracking appropriately at 90% maximum heart rate (HRmax)). Coefficient of variations (CoVs) of global ϵ values at rest was acceptable for both TVI and MST (7-12%), with low bias and narrow limits of agreement. Global SR data were less reliable for MST compared with TVI as demonstrated with CoV data (systolic SR=15 and 61%, early diastolic SR=16 and 17% and late diastolic SR=26 and 31% respectively). CoVs of global RV ϵ and SR obtained at 50% HRmax were acceptable using both techniques. As exercise intensity increased to 70 and 90% HRmax, reliability of ϵ and SR values reduced with larger variability in MST. We conclude that RV global and regional ϵ and SR data are feasible, comparable and reliable at rest and at 50% HRmax using both MST and TVI. Reliability was reduced during higher exercise intensities with only TVI acceptable for clinical and scientific use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of strain and strain rate parameters using two-dimensional speckle-tracking echocardiography in patients with coronary artery disease (Research Article)

The study aimed was to measure left ventricular (LV) strain using speckle tracking echocardiography (STE) for assessment of LV function. Eighty-two subjects (mean age 57±9 years) with suspected chest pain underwent two-dimensional (2D)-echocardiography before coronary angiography. Conventional echocardiographic parameters were used for the assessment of LV function. Longitudinal strain and its ...

متن کامل

Automated analysis of strain rate and strain: feasibility and clinical implications.

BACKGROUND This study evaluated 3 new automated methods, based on a combination of speckle tracking and tissue Doppler, for the analysis of strain rate (SR) and strain. Feasibility and values for peak systolic strain rate (SR s ) and end-systolic strain (S es ) were assessed. METHODS Thirty patients with myocardial infarction and 30 normal subjects were examined. Customized software with auto...

متن کامل

Cardiac magnetic resonance feature tracking: a novel method of assessing myocardial strain. Comparison with echocardiographic speckle tracking in healthy volunteers and in patients with left ventricular hypertrophy

Background: Left ventricular longitudinal strain (LV-LS) and strain rate (SR) are sensitive markers of early systolic dysfunction. Aim: To evaluate the feasibility of a novel, cardiac magnetic resonance (CMR) based method known as feature tracking (FT) for the assessment of strain and SR, and to compare the CMR based results to those obtained on standard transthoracic echocardiography (TTE) in ...

متن کامل

Speckle-Tracking and Tissue-Doppler Stress Echocardiography in Arterial Hypertension: A Sensitive Tool for Detection of Subclinical LV Impairment

Early diagnosis of cardiac alterations in hypertensive heart disease is still challenging. Since such patients might have depressed global LV systolic strain or strain rate when EF is still normal, speckle-tracking echocardiography (STE) and tissue-Doppler imaging (TDI) combined with stress echocardiography might improve early diagnosis of cardiac alterations. In this prospective study standard...

متن کامل

Quantification of left atrial strain and strain rate using Cardiovascular Magnetic Resonance myocardial feature tracking: a feasibility study

BACKGROUND Cardiovascular Magnetic Resonance myocardial feature tracking (CMR-FT) is a quantitative technique tracking tissue voxel motion on standard steady-state free precession (SSFP) cine images to assess ventricular myocardial deformation. The importance of left atrial (LA) deformation assessment is increasingly recognized and can be assessed with echocardiographic speckle tracking. Howeve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2014