Development and Validation of a Stability-Indicating RP-HPLC Method for the Estimation of Drotaverine Impurities in API and Pharmaceutical Formulation
نویسندگان
چکیده
A sensitive, stability-indicating gradient RP-HPLC method with PDA detection has been developed for the simultaneous analysis of drotaverine impurities in active pharmaceutical ingredient (API) and pharmaceutical formulations. Efficient chromatographic separation was achieved on an XTerra RP18, 150 × 4.6 mm, 5 μm column using gradient elution at 230 nm detection wavelength. The optimized mobile phase consisted of a 0.02 M potassium dihydrogen orthophosphate buffer of pH 3.0 as solvent A and acetonitrile as solvent B. The flow rate of the mobile phase was 1.0 mL min(-1) with a column temperature of 25°C. The method showed linearity over the range of 0.251-10.033 μg/mL, 0.231-9.995 μg/mL, 0.230-10.089 μg/mL, 0.334-10.011 μg/mL, and 0.324-10.050 μg/mL for impurities 1, 2, 3, 4, and drotaverine, respectively, with a correlation coefficient greater than 0.999. The relative retention times and relative response factors of impurities 1, 2, 3, 4 were 0.36, 0.90, 1.42, 1.55 and 1.04, 0.84, 1.10, 1.30, respectively. The drotaverine formulation sample was subjected to the stress conditions of acid, base, oxidative, thermal, humidity, and photolytic degradation. Drotaverine was found to degrade significantly in peroxide, base, and heat stress conditions. The degradation products were well-resolved from drotaverine and its impurities. The peak purity test results confirmed that the drotaverine peak was homogenous and pure in all stress samples and the mass balance was found to be more than 98%, thus proving the stability-indicating power of the method. The developed method was validated according to ICH guidelines with respect to specificity, linearity, limit of detection and quantification, accuracy, precision, and robustness.
منابع مشابه
Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملA New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms
A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms. Abstract The objective of the work is to develop and validate a new, simple, highly sensitive, stability indicating RP-HPLC method for simultaneous estimation of Dolutegravir and Rilpivirine in bulk and its dosage f...
متن کاملA stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation
The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...
متن کاملA stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation
The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...
متن کامل