Sonographic assessment of fatty liver: intraobserver and interobserver variability.

نویسندگان

  • Mustafa Cengiz
  • Senem Sentürk
  • Bulent Cetin
  • Aylin Hasanefendioğlu Bayrak
  • Senem Uysal Bilek
چکیده

Non-alcoholic fatty liver disease (NAFLD) is a common liver disease worldwide and ultrasonography is widely used in the diagnosis and the follow-up we purposed to assess intraobserver and interobserver variability in the sonographic evaluation of the existence and steatosis grades of NAFLD. Alanine aminotransferase (ALT) and aspartate aminotransferase (AST) levels and AST to ALT (AST/ALT) ratio were compared between the grades of hepatosteatosis. Hepatic ultrasonography (US) examinations consisted of 5-10 static images of 113 successive adult patients, whose records were in the picture archiving and communication system (PACS) of our hospital were retrospectively evaluated by two experienced radiologists. Hepatic images were graded into 4 groups; as normal, mild, moderate or severe hepatic steatosis. Evaluation of hepatic steatosis of the same set of images was repeated after one month under the same conditions. Interobserver and intraobserver agreement was assessed by using kappa (κ) statistics. In each group, the percentage of individuals with high ALT and/or AST, or AST/ALT ratio over 1 was calculated. The intraobserver agreement was 51%, fair kappa (κ=0.356) for observer 1; and 68%, moderate (κ=0.591) for observer 2. The interobserver agreements in the initial and second readings were 39% and 40%, fair (κ=0.208) and (κ=0.225), respectively. Elevations of ALT and/or AST levels were similar between groups depending on the degree of hepatosteatosis among the patients. Visual assessment of NAFLD by ultrasonography has substantial interobserver variability, and reproducibility of results is limited. More objective imaging modalities are needed to evaluate the degree of hepatosteatosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی پایایی درون مشاهده‌گر و بین مشاهده‌گر در ارزیابی هیستوپاتولوژیک لیکن پلان دهانی بر اساس معیارهای modified WHO

Background and Aims: In 1978 WHO (World health organization) formulated a histopathological definition for diagnosis of OLP (oral lichen planus). Previous studies showed that diagnosis of OLP with these criteria are not reproducible. In 2003 Van der Meij et al. represented new clinical and histopathologic definition for diagnosis of OLP known as modified WHO criteria. The purpose of this study ...

متن کامل

Interobserver and Intraobserver Agreement of Sonographic BIRADS Lexicon in the Assessment of Breast Masses

BACKGROUND BI-RADS was first developed in 1993 for mammography and in 2003 it was redesigned for ultrasonography (US). If the observer agreement is high, the method used in the classification of lesion would be reproducible. OBJECTIVES The aim of this study is to evaluate the inter- and intraobserver agreement of sonographic BI-RADS lexicon in the categorization and feature characterization o...

متن کامل

The interobserver and intraobserver reliability of the Fernandez classification of distal radius fracture

 Abstract Background: With increasing knowledge concerning fractures of the distal radius, different classifications have been proposed. Reliability of most of these classifications has been assessed. The Fernandez classification has never been assessed for intraobserver and interobserver reliability, although this classification is commonly used. Methods: Five observers including one attending...

متن کامل

Intra and Interobserver Reliability and Agreement of Semiquantitative Vertebral Fracture Assessment on Chest Computed Tomography

OBJECTIVES To evaluate the reliability of semiquantitative Vertebral Fracture Assessment (VFA) on chest Computed Tomography (CT). METHODS Four observers performed VFA twice upon sagittal reconstructions of 50 routine clinical chest CTs. Intra- and interobserver agreement (absolute agreement or 95% Limits of Agreement) and reliability (Cohen's kappa or intraclass correlation coefficient(ICC)) ...

متن کامل

Measuring blood pressure in the elderly: does atrial fibrillation increase observer variability?

OBJECTIVE To compare the interobserver and intraobserver variability of blood pressure measurements in geriatric patients in atrial fibrillation and in sinus rhythm. DESIGN Prospective assessment of blood pressure measurements carried out in random order in two groups of elderly patients by five doctors unaware of the aims of the study. SETTING Acute assessment wards for geriatric medicine,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of clinical and experimental medicine

دوره 7 12  شماره 

صفحات  -

تاریخ انتشار 2014