Determination of PAH in food samples by HPLC with fluorimetric detection following sonication extraction without sample clean-up.

نویسندگان

  • M J Nieva-Cano
  • S Rubio-Barroso
  • M J Santos-Delgado
چکیده

A rapid method is proposed for the determination of 16 polycyclic aromatic hydrocarbons (PAH) in non-fatty food (mashed potato, potato and toasted bread samples) based on their extraction with ethyl ether-methylene chloride (1:1) by sonication, and subsequent separation by high-performance liquid chromatography (HPLC) with fluorimetric detection. A Hypersil Green PAH column was used with a gradient of acetonitrile-water as the mobile phase, together with a programme of ten excitation and emission wavelength pairs. At levels 1.60-2320 microg kg(-1), mean recoveries of PAH were in the range 70-86% for mashed potato, potato and toasted bread samples. The relative standard deviations were in the range 4.2-11% (n = 6). Total PAH found in mashed potato were in the range 9.35-17.1 microg kg(-1), in potato samples 8.47-17.2 microg kg(-1) and in toasted bread samples 7.38-18.0 microg kg(-1), with relative standard deviations in the range 0.8-12%. Only chrysene, determined in Ortiz toasted bread (7.38 microg kg(-1)), has carcinogenic properties.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The potential of low temperature extraction method for analysis of polycyclic aromatic hydrocarbons in refined olive and refined pomace olive oils by HPLC/FLD

Background and Objectives: A method was developed and validated for determining 15 polycyclic aromatic hydrocarbons (PAHs) in refined olive and refined pomace olive oils using high performance liquid chromatography coupled with a fluorescence detector. Materials and Methods: The sample preparation involved liquid–liquid extraction with organic solvent and low temperature clean-up. The low temp...

متن کامل

Determination of Some Polycyclic Aromatic Hydrocarbons in the Caspian Seawater by HPLC Following Preconcentration with Solid-Phase Extraction

A solid-phase extraction (SPE) method for sample clean-up and preconcentration followed by reversed-phase high-performance liquid chromatography (RP-HPLC) with uv detection is reported for determination of polycyclic aromatic hydrocarbons (PAHs) in the caspian seawater. A good resolution was obtained using acetonitrile:water (40:60) as mobile-phase for separation of these compounds. The eff...

متن کامل

Determination of Polycyclic Aromatic Hydrocarbons in Olive and Refined Pomace Olive Oils using HPLC/FLD

ABSTRACT: In this study, an analytical method is developed to determine 15 polycyclic aromatic hydrocarbons (PAHs) in olive and refined pomace olive oils using HPLC coupled with a fluorescence detector. The standardised method of ultrasound-assisted solvent extraction consisted of liquid–liquid extraction with organic solvent and purification on C18 and Florisil bonded-phase cartridges was modi...

متن کامل

Modified Analytical Method for Polycyclic Aromatic Hydrocarbons, Using Rp-hplc with Fluorescence Detection and Sec for Sample

An HPLC method with fluorescence detection has been developed for determination of eight polycyclic aromatic hydrocarbons (PAH) with four to six condensed aromatic carbon rings in edible oils and smoked products. The method employs preparative size-exclusion chromatography for efficient one-step lipid removal without saponification; benzo[b]chrysene is used as internal standard for quantificati...

متن کامل

An Ion-pair Dispersive Liquid-Liquid Microextraction for Simultaneous Determination of Synthetic Dyes in Ice Cream Samples by HPLC

An efficient, sensitive and fast method was developed based on an ultrasound-assisted extraction followed by an ion-pair dispersive liquid-liquid microextraction (USAE-IP-DLLME) for the simultaneous determination of five commonly used synthetic sulfonate dyes (tartarazine, quinoline yellow, sunset yellow, azorubine, and brilliant blue) in ice cream samples using high performance liquid chromato...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 126 8  شماره 

صفحات  -

تاریخ انتشار 2001