Illustrative Multi-volume Rendering for PET/CT Scans
نویسندگان
چکیده
In this paper we present illustrative visualization techniques for PET/CT datasets. PET/CT scanners acquire both PET and CT image data in order to combine functional metabolic information with structural anatomical information. Current visualization techniques mainly rely on 2D image fusion techniques to convey this combined information to physicians. We introduce an illustrative 3D visualization technique, specifically designed for use with PET/CT datasets. This allows the user to easily detect foci in the PET data and to localize these regions by providing anatomical contextual information from the CT data. Furthermore, we provide transfer function specifically designed for PET data that facilitates the investigation of interesting regions. Our technique allows users to get a quick overview of regions of interest and can be used in treatment planning, doctor-patient communication and interdisciplinary communication. We conducted a qualitative evaluation with medical experts to validate the utility of our method in clinical practice.
منابع مشابه
Background-Based Delineation of Internal Tumor Volumes on Static Positron Emission Tomography in a Phantom Study
Objective(s): Considering the fact that the standardized uptake value (SUV) of a normal lung tissue is expressed as x±SD, x+3×SD could be considered as the threshold value to outline the internal tumor volume (ITV) of a lung neoplasm. Methods: Three hollow models were filled with 55.0 kBq/mL fluorine18- fluorodeoxyglucose (18F-FDG) to represent tumors. The models were fixed to a barrel filled w...
متن کاملRetroperitoneal fibrosis as a cause of positive FDG PET/CT.
This article educates the reader on idiopathic retroperitoneal fibrosis and emphasizes the importance of considering conditions that mimic this disease on PET/CT through an illustrative case of a 58 year-old man presenting with intermittent abdominal, back, and scrotal pain undergoing successive PET/CT scans, both for diagnosis and following treatment.
متن کاملBlind spots at oncological CT: lessons learned from PET/CT
Improved accuracy in oncological computed tomography (CT) could lead to a decrease in morbidity and improved survival for oncology patients. Visualization of metabolic activity using the glucose analogue [(18)F]fluorodeoxyglucose (FDG) in combination with the high anatomic resolution of CT in an integrated positron emission tomography (PET)/CT examination has the highest sensitivity and specifi...
متن کاملImpact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer
AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...
متن کاملThe impact of stereo-visualisation of three-dimensional CT datasets on the inter- and intraobserver reliability of the AO/OTA and Neer classifications in the assessment of fractures of the proximal humerus.
We evaluated the impact of stereo-visualisation of three-dimensional volume-rendering CT datasets on the inter- and intraobserver reliability assessed by kappa values on the AO/OTA and Neer classifications in the assessment of proximal humeral fractures. Four independent observers classified 40 fractures according to the AO/OTA and Neer classifications using plain radiographs, two-dimensional C...
متن کامل