Neutron spectroscopy as a fuel ion ratio diagnostic: lessons from JET and prospects for ITER.

نویسندگان

  • G Ericsson
  • S Conroy
  • M Gatu Johnson
  • E Andersson Sundén
  • M Cecconello
  • J Eriksson
  • C Hellesen
  • S Sangaroon
  • M Weiszflog
چکیده

The determination of the fuel ion ratio n(t)/n(d) in ITER is required at a precision of 20%, time resolution of 100 ms, spatial resolution of a/10, and over a range of 0.016 keV and for n(T)/n(D)<0.6. A crucial issue is the signal-to-background situation in the measurement of the weak 2.5 MeV emission from DD reactions in the presence of a background of scattered 14 MeV DT neutrons. Important experimental input and corroboration for this assessment are presented from the time-of-flight neutron spectrometer at JET where the presence of a strong component of backscattered neutrons is observed. Neutron emission components on ITER due to beam-thermal and tritium-tritium reactions can further enhance the prospects for NES.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of DT and DD neutrons with a TOF spectrometer for determination of fuel ion density ratio in ITER

Measurement of the fuel ion density ratio, nD/nT, is required for burning control in ITER. The measured nD/nT ratio must be fed back in real time. A neutron measurement system to measure nD/nT should be operable at high counting rate. The estimated number of emitted DT neutrons is 200 times higher than that of DD neutrons under the ITER standard operation conditions. A neutron measurement syste...

متن کامل

High resolution fast wave reflectometry: JET design and implications for ITER.

The measurement of the fuel mixture remains a very difficult task in thermonuclear plasmas, where the hydrogen isotopes are fully stripped and do not emit line radiation. On the other hand, direct determination of the ion species mix will be essential in the reactor to keep the mixture close to 50/50 and maximize the fusion output. In this paper, the design of fast wave reflectometry for JET is...

متن کامل

Development of novel fuel ion ratio diagnostic techniques.

To overcome the challenge of measuring the fuel ion ratio in the core (ρ<0.3) of ITER, a coordinated effort aiming at developing diagnostic techniques has been initiated. The investigated techniques are novel uses or further development of existing methods such as charge exchange recombination spectrometry, neutron spectrometry, and collective Thomson scattering. An overview of the work on the ...

متن کامل

Prospects for Core Helium Density and Related Measurements on Iter Using Active Charge Exchange

The measurement of low-Z impurities, in particular He ash, in the core of International Thermonuclear Experimental Reactor (ITER) remains an outstanding diagnostic issue. The only credible candidate at present is active charge exchange recombination spectroscopy (CER) utilizing a diagnostic neutral beam (DNB) optimized for the dual requirements of beam penetration and charge exchange cross sect...

متن کامل

Polysulfone-based Anion Exchange Membranes for Potential Application in Solid Alkaline Fuel Cells

In present research work, anion exchange membranes based on quaternized polysulfone with ammonium cation moieties (QAPSF) were prepared by chloromethylation, amination and alkalization. The chloromethylated polysulfone were characterized by 1HNMR spectroscopy and functionalization degree was determined according to peak area integration. Ion transport properties (ionic conductivity, ion exchang...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 81 10  شماره 

صفحات  -

تاریخ انتشار 2010