Does parallel conductance vary during systole in the human right ventricle?

نویسندگان

  • P A White
  • R R Chaturvedi
  • A J Bishop
  • C I Brookes
  • P J Oldershaw
  • A N Redington
چکیده

OBJECTIVES Right ventricular (RV) contractile performance remains poorly characterised, particularly in humans. Conductance catheter techniques have the potential to overcome the geometric difficulties in RV volume measurement that have hindered systematic studies of RV pressure volume relations. The present study examines changes in parallel conductance (Vc) that may occur during the cardiac cycle in the human right ventricle. METHODS Using signals obtained from custom-built conductance catheters, six isochronal systolic values of Vc (Vc(t)) were measured during hypertonic saline wash-in. Studies were performed in nine patients undergoing right heart catheterisation. Their ages ranged from 7 to 39 years (median = 16) and their weights ranged from 20.3 to 84.7 kg (median = 50.0 kg). Measurements of mean Vc and isochronal Vc(t) and its variability during systole were assessed. Mean Vc was measured using the Baan technique (Vc(Baan)), Vc(t) was measured from six systolic isochrones obtained during the same period of hypertonic saline wash-in. RESULTS The temporal changes in Vc(t) were small (mean 5.8%, median = 4.4%, range = 0.6-17.9%) of total corrected end-diastolic volume (mean maximal variation of 7.7 ml). The value of Vc(t) obtained at dp/dtmax (mean = 99.1 ml; median = 104.75 ml; range 20.15-196.7 ml) was not significantly different to that obtained at dp/dtmin (mean = 100.0 ml; median = 110.87 ml; range = 20.0-204.2 ml) (P > 0.05), but both were higher than the single Vc measurement (Vc(Baan)) obtained using the standard approach (P = 0.02). The correlation between Vc(Baan) and Vc(t) for group data; (Vc(Baan) = 89.69 ml, s.d. = 43.73 ml; Vc(t) = 98.16 ml, s.d. = 50.16 ml) produces a regression slope of 0.99 for all studies (P = 0.02). CONCLUSION We conclude that parallel conductance does vary during systole in the human right ventricle of adults and older children after repair of congenital abnormalities but there is no significant difference in Vc(t) at dp/dtmin and dp/dtmax. However, there was a significant difference when the isochronal Vc(t) measurement is compared with the standard single value technique (Vc(Baan)) obtained using the hypertonic saline wash-in method. The excellent correlation between Vc(t) and Vc(Baan) suggests that the correction of Vc for the phase of the cardiac cycle is unnecessary for most purposes when studying the human right ventricle.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Right ventricular volume measurement by conductance catheter.

Continuous ventricular volume measurement by the conductance method assumes a homogeneous electrical field dispersed throughout and contained within the ventricle. Because of dense trabeculation and complex geometry, right ventricular (RV) volume description by this method may be seriously compromised. This study sought to determine the accuracy and limitations of RV volume measurement by condu...

متن کامل

The effect of right ventricular filling on the pressure-volume relationship of ejecting canine left ventricle.

Acute shifts in the pressure-volume relationship of the left ventricle occur under several conditions. One potential mechanism for this phenomenon is ventricular interdependence, that is, the influence of right ventricular filling on the left ventricle. This mechanism was studied in an isolated cross-circulated ejecting canine heart preparation with balloons sewn into both right and left ventri...

متن کامل

Simultaneous LV and RV volumes by conductance catheter: effects of lung insufflation on parallel conductance.

One aspect in the measurement of ventricular volume using the conductance catheter technique is the assessment of parallel electrical conductivity of structures extrinsic to the ventricular blood pool. Because it is sometimes necessary to make volume measurements during ventilation or spontaneous respiration, the extent to which parallel conductance may vary with lung insufflation was investiga...

متن کامل

The Physiology of the Alligator Heart: the Cardiac Cycle

Pressure recordings from the heart and major arteries of the alligator show that a conventional relationship exists between the left ventricle and the right aorta. Pressure gradients from ventricle to aorta during systole are very small. Right aortic blood flow rises rapidly to a single peak and then falls more gradually until aortic valve closure. The right ventricle is connected both to the p...

متن کامل

Echocardiographic abnormalities in children with obstructive breathing disorders during sleep.

OBJECTIVES To assess cardiac morphology and function by means of echocardiograms of children with obstructed breathing while asleep. METHODS The study enrolled 40 children of both sexes, aged from 3 to 11 years; 30 of them had obstructed breathing during sleep (group I) and 10 children were healthy controls (group II). The two groups were similar in terms of sex, age, weight and height. The 4...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cardiovascular research

دوره 32 5  شماره 

صفحات  -

تاریخ انتشار 1996