Experimental flat-panel high-spatial-resolution volume CT of the temporal bone.

نویسندگان

  • Rajiv Gupta
  • Soenke H Bartling
  • Samit K Basu
  • William R Ross
  • Hartmut Becker
  • Armin Pfoh
  • Thomas Brady
  • Hugh D Curtin
چکیده

BACKGROUND AND PURPOSE A CT scanner employing a digital flat-panel detector is capable of very high spatial resolution as compared with a multi-section CT (MSCT) scanner. Our purpose was to determine how well a prototypical volume CT (VCT) scanner with a flat-panel detector system defines fine structures in temporal bone. METHODS Four partially manipulated temporal-bone specimens were imaged by use of a prototypical cone-beam VCT scanner with a flat-panel detector system at an isometric resolution of 150 microm at the isocenter. These specimens were also depicted by state-of-the-art multisection CT (MSCT). Forty-two structures imaged by both scanners were qualitatively assessed and rated, and scores assigned to VCT findings were compared with those of MSCT. RESULTS Qualitative assessment of anatomic structures, lesions, cochlear implants, and middle-ear hearing aids indicated that image quality was significantly better with VCT (P < .001). Structures near the spatial-resolution limit of MSCT (e.g., bony covering of the tympanic segment of the facial canal, the incudo-stapedial joint, the proximal vestibular aqueduct, the interscalar septum, and the modiolus) had higher contrast and less partial-volume effect with VCT. CONCLUSION The flat-panel prototype provides better definition of fine osseous structures of temporal bone than that of currently available MSCT scanners. This study provides impetus for further research in increasing spatial resolution beyond that offered by the current state-of-the-art scanners.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution secondary reconstructions with the use of flat panel CT in the clinical assessment of patients with cochlear implants.

Radiologic assessment of cochlear implants can be limited because of metallic streak artifacts and the high attenuation of the temporal bones. We report on 14 patients with 18 cochlear implants (17 Med-El standard 31.5-mm arrays, 1 Med-El medium 24-mm array) who underwent flat panel CT with the use of high-resolution secondary reconstruction techniques. Flat panel CT depicted the insertion site...

متن کامل

Temporal bone imaging: comparison of flat panel volume CT and multisection CT.

BACKGROUND AND PURPOSE A recent development in radiology is the use of flat panel detectors in CT to obtain higher-resolution images. This technique is known as flat panel volume CT (fpVCT). We sought to compare the image quality and diagnostic value of 2 different flat panel detector-equipped scanners: one is a prototype fpVCT scanner, and the other is a so-called flat panel digital volume tom...

متن کامل

Design of Small Animal Computed Tomography Imaging for in vitro and in vivo Studies

Introduction: Mini Computed Tomography (mini-CT) was suggested in biomedical research to investigate tissues and small animals. We present designed and built a mini x-ray computed tomography (mini-CT) for small animals as well as industrial component imaging. Materials and Methods: The system used in this study includes a X-ray tube 20kV to 160kV and a flat pa...

متن کامل

Diagnostic value of CT and MRI of Temporal Bone in Cochlear Implantation Candidates

Background Cochlear implantation is an approved treatment which can be used to treat severe to profound hearing loss. Imaging before cochlear implant surgery is very important in decision making and assessing the temporal bone anatomy for surgery. We aimed to assess the diagnostic value of high resolution CT scan (HRCT), and MRI of temporal bone in candidate pati...

متن کامل

Generalized Penalized Weighted Least-Squares Reconstruction for Deblurred Flat-Panel CBCT

An increase in achievable spatial resolution would enable application of flat-panel detector cone-beam CT (FPCBCT) in high-resolution applications, such as 3D breast and bone imaging. Improved reconstruction techniques exploiting more sophisticated models of noise and spatial resolution characteristics may provide such improvement. In this work, we propose a statistical model of measurement mea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 25 8  شماره 

صفحات  -

تاریخ انتشار 2004