Detection of static cyclotorsion and compensation for dynamic cyclotorsion in laser in situ keratomileusis.

نویسندگان

  • Jean-Luc Febbraro
  • Douglas D Koch
  • Hamza N Khan
  • Alain Saad
  • Damien Gatinel
چکیده

PURPOSE To evaluate the degree of static and dynamic cyclotorsion using a rotational eye tracker in laser in situ keratomileusis (LASIK) to correct myopic astigmatism. SETTING Rothschild Foundation, Paris, France. DESIGN Cohort study. METHODS Laser in situ keratomileusis with active iris registration using a Zyoptix 100 Hz excimer laser with Advanced Control Eyetracking was performed in eyes with myopic astigmatism. In all cases, iris registration was used to evaluate the degree of static cyclotorsion preoperatively and the degree of dynamic cyclotorsion and intraoperatively. The direction, mean values, and ranges of static and dynamic cyclotorsion were recorded. The amplitude of intraoperative cyclotorsion was reported. RESULTS The study included 74 consecutive eyes (38 patients). The direction of cyclotorsion was not statistically significant. The mean static cyclotorsion was 3.08 degrees ± 2.68 (SD) (range -7.0 to 14.0 degrees) and the mean dynamic cyclotorsion, 3.39 ± 2.94 degrees (range -10.3 to 13.5 degrees). During photoablation, the mean amplitude of cyclotorsion was 2.69 ± 1.63 degrees (range 0.0 to 9.2 degrees). The magnitude of dynamic cyclotorsion was less than 5 degrees in 66% of eyes, 5 degrees or more in 34% of eyes, and 10 degrees or more in 4% of eyes. CONCLUSIONS Static and dynamic cyclotorsion was detected with a dynamic eye tracker in eyes having LASIK. Rotational movements were mainly static but had significant amplitude during photoablation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Static cyclotorsion measurements using the Schwind Amaris laser.

PURPOSE To assess the reliability and reproducibility of static cyclotorsion correction (SCC) measurements made using the Schwind Amaris Excimer laser in patients undergoing LASIK or PRK, and compare the outcomes of treating astigmatism with and without SCC. METHODS Eighty eyes of 40 patients were included in this study. All eyes underwent 2 or 3 sets of five measurements: before and after sp...

متن کامل

Active cyclotorsion error correction during LASIK for myopia and myopic astigmatism with the NIDEK EC-5000 CX III laser.

PURPOSE To investigate the predictability and accuracy of active cyclotorsion compensation during LASIK for myopia with astigmatism. METHODS Fifty-two eyes of 26 patients were divided into two groups; one group (30 eyes) underwent primary LASIK with torsion error correction (TEC [TEC group]) and 22 eyes underwent LASIK without TEC (control group). The NIDEK EC-5000 CX III excimer laser was us...

متن کامل

Excimer Laser Surgery: Biometrical Iris Eye Recognition with Cyclorotational Control Eye Tracker System

A prospective comparative study assessing the importance of the intra-operative dynamic rotational tracking-especially in the treatment of astigmatisms in corneal refractive Excimer laser correction-concerning clinical outcomes is presented. The cyclotorsion from upright to supine position was measured using iris image comparison. The Group 1 of patients was additionally treated with cyclorotat...

متن کامل

Refractive lenticule extraction (ReLEx) through a small incision (SMILE) for correction of myopia and myopic astigmatism: current perspectives

Small-incision lenticule extraction (SMILE) is an alternative to laser-assisted in situ keratomileusis (LASIK) and photorefractive keratectomy (PRK) for the correction of myopia and myopic astigmatism. SMILE can be performed for the treatment of myopia ≤-12 D and astigmatism ≤5 D. The technology is currently only available in the VisuMax femtosecond laser platform. It offers several advantages ...

متن کامل

Surgeon offsets and dynamic eye movements in laser refractive surgery.

PURPOSE To determine the amount of static and dynamic pupil decentrations that occur during laser refractive surgery. SETTING The Center of Visual Science and the Department of Ophthalmology, University of Rochester, Rochester, New York, USA. METHODS The surgeon's accuracy in aligning the pupil center with the laser center axis was measured when engaging the eye-tracker in 17 eyes receiving...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 36 10  شماره 

صفحات  -

تاریخ انتشار 2010