Effects of the pulsed electron avalanche knife on retinal tissue.

نویسندگان

  • Daniel V Palanker
  • Michael F Marmor
  • Andre Branco
  • Philip Huie
  • Jason M Miller
  • Steven R Sanislo
  • Alexander Vankov
  • Mark S Blumenkranz
چکیده

OBJECTIVES To evaluate the precision of retinal tissue dissection by the pulsed electron avalanche knife (PEAK) and to assess possible toxic effects from this device. METHODS To demonstrate precision of cutting, bovine retina (in vitro) and rabbit retina (in vivo) were incised with the PEAK. Samples were examined by scanning electron microscopy and histologic examination (light microscopy). To evaluate possible toxic effects in rabbit eyes, 30 000 pulses were delivered into the vitreous 1 cm above the retina. Histologic examinations and electroretinography were performed at intervals up to 1 month after exposure. RESULTS Cuts in postmortem bovine retina showed extremely sharp edges with no signs of thermal damage. Full-thickness cuts in living attached rabbit retina were similarly sharp and were typically less than 100 microm wide. No signs of retinal toxic effects were detected by histologic examination or electroretinography. CONCLUSIONS The PEAK is capable of precise cutting through retinal tissue, and there are no demonstrable retinal toxic effects from its use. The precision and tractionless nature of PEAK cutting offers advantages over mechanical tools and laser-based instrumentation. We believe this new device will prove useful in a variety of vitreoretinal surgical applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulsed electron avalanche knife (PEAK-fc) for dissection of retinal tissue.

OBJECTIVE To evaluate the effectiveness and precision of tractionless retinal tissue dissection by the advanced version of the pulsed electron avalanche knife for fine cutting (PEAK-fc; Carl Zeiss Meditec, Jena, Germany). METHODS Porcine retina (in vivo) and human retina (in vitro) were incised with the PEAK-fc using various pulse parameters. The globes were then processed for light microscop...

متن کامل

Anterior capsulotomy with a pulsed-electron avalanche knife.

PURPOSE To evaluate a new pulsed-electron avalanche knife design for creating a continuous curvilinear capsulotomy (CCC) and compare the CCC with a mechanical capsulorhexis. SETTING Department of Ophthalmology, Stanford University, Stanford, California, USA. METHODS In this study, CCCs were created in freshly enucleated bovine eyes and in rabbit eyes in vivo. The cutting velocity was adjust...

متن کامل

Pulsed electron avalanche knife in vitreoretinal surgery.

PURPOSE To evaluate the advantages, disadvantages, safety, and surgical applicability of the pulsed electron avalanche knife (PEAK-fc), a new electrosurgical knife for "cold" and tractionless cutting, in vitreoretinal surgery. PEAK-fc is equipped with an integrated fiberoptic that makes bimanual procedures in intraocular surgery possible. METHODS A prospective consecutive trial of 18 eyes in ...

متن کامل

Precision and safety of the pulsed electron avalanche knife in vitreoretinal surgery.

BACKGROUND We have developed a new surgical instrument, called the pulsed electron avalanche knife (PEAK; Carl Zeiss Meditec, Jena, Germany), for precise, "cold," and tractionless dissection of tissue in liquid media. OBJECTIVE To evaluate the 3-dimensional damage zone induced by the PEAK compared with 2 other standard intraocular surgical instruments, diathermy and retinal scissors. METHOD...

متن کامل

Pulsed electron avalanche knife (PEAK) for intraocular surgery.

PURPOSE To develop a better and more economical instrument for precise, tractionless, "cold" cutting during intraocular surgery. The use of highly localized electric fields rather than laser light as the means of tissue dissection was investigated. METHODS A high electric field at the tip of a fine wire can, like lasers, initiate plasma formation. Micrometer-length plasma streamers are genera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 120 5  شماره 

صفحات  -