Mixed venous O2 saturation and fluid responsiveness after cardiac or major vascular surgery
نویسندگان
چکیده
BACKGROUND It is unclear if and how SvO2 can serve as an indicator of fluid responsiveness in patients after cardiac or major vascular surgery. METHODS This was a substudy of a randomized single-blinded clinical trial reported earlier on critically ill patients with clinical hypovolemia after cardiac or major vascular surgery. Colloid fluid loading was done for 90 min, guided by changes in pulmonary artery occlusion pressure (PAOP) or central venous pressure (CVP). Fluid responsiveness was defined as ≥15% increase in cardiac index (CI). Hemodynamics, including transpulmonary dilution-derived global end-diastolic volume index (GEDVI) and global ejection fraction (GEF), were measured and blood samples taken. RESULTS Whereas baseline SvO2 (>70% in 68% of patients) did not differ, the SvO2 increased in patients responding to fluid loading (≥15% in CI in n = 26) versus those not responding (n = 11; P = 0.03). The increase in GEDVI was also greater in responders (P = 0.005). The area under the receiver operating characteristic curve for fluid responsiveness of changes in SvO2 was 0.73 (P = 0.007), with an optimal cutoff of 2%, and of those in GEDVI 0.82 (P < 0.001), while the areas did not differ. However, the value of SvO2 increases to reflect CI increases with fluid loading was greatest when GEF was ≤20% (in 53% of patients). CONCLUSIONS An increase in SvO2 ≥2%, irrespective of a relatively high baseline value, can thus be used as a monitor of fluid responsiveness in clinically hypovolemic patients after cardiac or major vascular surgery, particularly in those with systolic cardiac dysfunction. Fluid responsiveness concurs with increased tissue O2 delivery.
منابع مشابه
Lactate and venoarterial carbon dioxide difference/arterial-venous oxygen difference ratio, but not central venous oxygen saturation, predict increase in oxygen consumption in fluid responders.
OBJECTIVES During circulatory failure, the ultimate goal of treatments that increase cardiac output is to reduce tissue hypoxia. This can only occur if oxygen consumption depends on oxygen delivery. We compared the ability of central venous oxygen saturation and markers of anaerobic metabolism to predict whether a fluid-induced increase in oxygen delivery results in an increase in oxygen consum...
متن کاملHigh mixed venous oxygen saturation levels do not exclude fluid responsiveness in critically ill septic patients
INTRODUCTION The aim of this study was to determine whether the degree of fluid responsiveness in critically ill septic patients is related to baseline mixed venous oxygen saturation (SvO2) levels. We also sought to define whether fluid responsiveness would be less likely in the presence of a high SvO2 (>70%). METHODS This observational study was conducted in a 32-bed university hospital medi...
متن کاملEffects of arterial oxygen tension and cardiac output on venous saturation: a mathematical modeling approach
OBJECTIVES Hemodynamic support is aimed at providing adequate O2 delivery to the tissues; most interventions target O2 delivery increase. Mixed venous O2 saturation is a frequently used parameter to evaluate the adequacy of O2 delivery. METHODS We describe a mathematical model to compare the effects of increasing O2 delivery on venous oxygen saturation through increases in the inspired O2 fra...
متن کاملEffects of amrinone on cardiac index, venous oxygen saturation and venous admixture in patients recovering from cardiac surgery.
The hemodynamic and oxygen transport effects of low-dose (0.75 mg/kg loading dose + 10 micrograms/kg/min infusion, n = 12) and high-dose (2.25 mg/kg loading dose + 20 micrograms/kg/min infusion, n = 12) amrinone were evaluated in extubated patients 24 h after CABG. At both doses, amrinone significantly (p less than 0.05) increased HR, but decreased mean arterial, mean pulmonary artery, central ...
متن کاملPleth variability index and fluid responsiveness of hemodynamically stable patients after cardiothoracic surgery.
BACKGROUND Fluid responsiveness is a measure of preload dependence and is defined as an increase in cardiac output due to volume expansion. Recent publications have suggested that variation in amplitude of the pulse oximetry waveform may be predictive of fluid responsiveness. The pleth variability index (PVI) was developed as a noninvasive bedside measurement of this variation in the pulse oxim...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -