A Novel Approach in Design of a Fuzzy Based Shunt Active Power Filter for the Enhancement of Power Quality
نویسنده
چکیده
Active power filters most of the times are employed for elimination of the harmonics created by non-linear loads in power system and for reactive power compensation of linear and non-linear loads. Compensating current is sent by shunt active power filter (SAF) at Point of Common Coupling (PCC) to mitigate current harmonics in the line. Hence sinusoidal nature of current and voltage waveforms are reintroduced. Usually shunt active power filters are connected in parallel with non-linear and reactive loads. Fuzzy logic controller is used as it doesn’t require complex mathematical model. Filter inductor current is shaped by fuzzy controller so that line current is in phase with and of input voltage shape. Simulation of the proposed filter is carried out using MATLAB/SIMULINK.
منابع مشابه
A Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach
This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...
متن کاملMitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach
This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...
متن کاملActive Power Filter Design by a Novel Approach of Multi-Objective Optimization
This paper presents an innovative active power filter design method to simultaneously compensate the current harmonics and reactive power of a nonlinear load. The power filter integrates a passive power filter which is a RL low-pass filter placed in series with the load, and an active power filter which comprises an RL in series with an IGBT based voltage source converter. The filter is assumed...
متن کاملA Novel Approach for Enhancement of Power Quality by Reduction of Total Harmonic Disortion in Three Phase Four Wire System
This paper presents a fuzzy logic, PI, average current controlled shunt active power filter used to compensate for harmonic distortion in three-phase four-wire systems. The shunt active filter employs a simple method for the calculation of the reference compensation current based on Fast Fourier Transform. The presented Shunt Active Power filter is able to operate in balanced, unbalanced and Va...
متن کاملA Hybrid Control Method for Stable Operation of Active Power Filters in Three-Phase Four-Wire Networks
The main goal of this study is the use of Lyapunov’s stability theory to a three-phase four-wire shunt active power filter (SAPF), since this method has been applied effectively to other areas of converter. The dynamic model of the SAPF is first established, after that, a combination of fuzzy tracking control and Lyapunov function is suggested in order to impose a desired transient waveform on ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2014