Shear-induced detachment of biofilms from hollow fiber silicone membranes.

نویسندگان

  • Z Huang
  • E S McLamore
  • H S Chuang
  • W Zhang
  • S Wereley
  • J L C Leon
  • M K Banks
چکیده

A suite of techniques was utilized to evaluate the correlation between biofilm physiology, fluid-induced shear stress, and detachment in hollow fiber membrane aerated bioreactors. Two monoculture species biofilms were grown on silicone fibers in a hollow fiber membrane aerated bioreactors (HfMBR) to assess detachment under laminar fluid flow conditions. Both physiology (biofilm thickness and roughness) and nutrient mass transport data indicated the presence of a steady state mature biofilm after 3 weeks of development. Surface shear stress proved to be an important parameter for predicting passive detachment for the two biofilms. The average shear stress at the surface of Nitrosomonas europaea biofilms (54.5 ± 3.2 mPa) was approximately 20% higher than for Pseudomonas aeruginosa biofilms (45.8 ± 7.7 mPa), resulting in higher biomass detachment. No significant difference in shear stress was measured between immature and mature biofilms of the same species. There was a significant difference in detached biomass for immature vs. mature biofilms in both species. However, there was no difference in detachment rate between the two species.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CO2 Capture by Dual Hollow Fiber Membrane Systems

In this paper, a system for efficient removal of carbon dioxide by hollow fiber membranes is proposed. The system is compact, and it is very useful for application in the offshore energy industries. In particular, it is used to removing CO2 from the exhaust of power generation facilities on offshore platforms.The proposed dual membrane contactor contains two types of membranes (polypropylene me...

متن کامل

Fabrication of Crosslinkable Hollow Fiber Membranes for Pervaporation Dehydration

Integrally-skinned asymmetric Polyetherimide/Poly (vinyl alcohol) (PEI/PVA) hollow fber membranes for pervaporation dehydration were fabricated by non-solvent induced phase inversion. PVA inside the PEI matrix could be crosslinked to provide membrane performance stability during long term operation. The effects of different PEI/PVA blend ratio, external coagulant type and...

متن کامل

Mathematical Modeling of Carbon Dioxide Removal from the CO2/CH4 Gas Mixture Using Amines and Blend of Amines in Polypropylene: A Comparison between Hollow Fiber Membrane Contactor and Other Membranes

In this work, a mathematical model is established to describe the removal of CO2 from gaseous mixtures including CH4 and CO2 in a polypropylene hollow fiber membrane contactor in the presence of conventional absorbents such as monoethanolamine (MEA), methyldiethanolamine (MDEA), and a blend of them. Modeling was performed in axial and radial directions under the fully-wet condition for counterc...

متن کامل

Fabrication and Characterization of Polyetherimide Hollow Fiber Membrane Contactor for Carbon Dioxide Stripping from Monoethanolamine Solution

In this research, process asymmetric polyetherimide hollow fiber membranes using ethanol (0, 2 and 4 wt%) as non-solvent additive in the polymer dope via phase inversion method were fabricated. Aqueous solution of 1-methyl-2-pyrrolidine (NMP) (90%) was applied as a bore fluid to avoid inner skin layer formation and water was used as the external coagulant. The morphology of fabricated membranes...

متن کامل

Fabrication and Modification of Thin-Film Composite Hollow Fiber NF Membranes

This study focuses on the preparation and modification of a thin-film composite (TFC) hollow fiber polyamide membrane fabricated by the interfacial polymerization of Piperazine (PIP) and trimesoyl chloride (TMC) on a porous polysulfone substrate. The effects of triethylenetetramine (TETA) and silica nanoparticles (SiO2) contents in the aqueous phase (as the additives) on the morphology and perf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biotechnology and bioengineering

دوره 110 2  شماره 

صفحات  -

تاریخ انتشار 2013