Urgent surgical management for embolized occluder devices in childhood: single center experience
نویسندگان
چکیده
BACKGROUND In this study, we sought to analyze our experience in urgent surgical management for embolized cardiac septal and ductal occluder devices resulting from trans-catheter closure of atrial septal defect, ventricular septal defect and patent ductus arteriosus in childhood patient group. METHODS We retrospectively reviewed 9 patients (aged 2-15 years) who underwent urgent surgery due to cardiac septal and ductal occluder embolization between January 2007 and December 2010. Congenital defects were atrial septal defect (n = 6), ventricular septal defect (n = 1), and patent ductus arteriosus (n = 2). Risk factors for device embolization and urgent surgical management techniques for embolized device removal were discussed. RESULTS Removal of embolized devices in all cases and repair of damaged tricuspid valve in 2 patients were performed. Inevitably, all congenital defects were closed or ligated up to the primary defect. Total circulator arrest necessitated in 1 patient with ascending aortic device embolization. All operations were completed successfully and no hospital mortality or morbidity was encountered. CONCLUSIONS Although closure of left to right shunting defects by percutaneous occluder devices has a lot of advantages, device embolization is still a major complication. If embolized device retrieval fails with percutaneous intervention attempts, surgical management is the only method to remove embolized devices. In this circumstance, to provide an uneventful perioperative course, urgent management strategies should be well planned.
منابع مشابه
Urgent Surgical Intervention for Embolized Cardiac Occluder Devices: A Case Series
Introduction: In this study, we sought to illustrate our experience in urgent surgical management for embolized cardiac septal occlude devices resulting from trans-catheter closure of atrial septal defect and ventricular septal defect. Mathrials and Methods: We retrospectively reviewed four patients aged 2–10 years who underwent urgent surgery due to cardiac septal occluder embolization between...
متن کاملSuccessful Percutaneous Retrieval of Embolized Septal Occluder Device from Aortic Arch and Placement of a Newer Septal Occluder Device in Combined Procedure
Embolization of the Amplatzer Septal Occluder (ASO) device (St. Jude Medical, Minnesota) after percutaneous closure of atrial septal defect (ASD) is a rare and potentially catastrophic complication. Percutaneous retrieval of the embolized device is gaining ground as an acceptable method, although these patients are usually subsequently referred for open surgical closure of the ASD. We present a...
متن کاملTough, but not impossible – Retrieval of large atrial septal occluder devices embolized to left atrium
Atrial septal defect (ASD) is a congenital heart defect that is being increasingly treated using percutaneous interventions. However, these techniques are not devoid of complications. One such complication is device embolization. Removal of such closure device poses tremendous risk and consequent complications both by percutaneous retrieval and surgical removal. Herein, we present two cases of ...
متن کاملPercutaneous closure of traumatic ventricular septal defects: device selection and reasoning
A ventricular septal defect (VSD) is one or more holes in the wall that separates the right and left ventricles of the heart. VSD is one of the most common congenital (present from birth) heart defects. Many types of VSDs have been reported, including congenital VSDs, post-infarction VSDs (1), and post-traumatic VSDs (2). Furthermore, there are four types of congenital VSDs; perimembranous VSD ...
متن کاملPercutaneous Retrieval of Embolized Amplatzer Septal Occluder after Treatment of Double Atrial Septal Defect: A Case Report
Embolization of the occlusion device after percutaneous closure of atrial septal defect (ASD) is a potential disastrous complication. The usual site of embolization is the right side of the heart including pulmonary artery, but the device embolization to the extracardiac aorta is extremely rare. Here, we report a successful percutaneous retrieval case of the embolized Amplatzer Septal Occluder ...
متن کامل