The origin of Korotkoff sounds and the accuracy of auscultatory blood pressure measurements.
نویسنده
چکیده
This study explores the hypothesis that the sharper, high frequency Korotkoff sounds come from resonant motion of the arterial wall, which begins after the artery transitions from a buckled state to an expanding state. The motions of one mass, two nonlinear springs, and one damper, driven by transmural pressure under the cuff, are used to model and compute the Korotkoff sounds according to principles of classical Newtonian physics. The natural resonance of this spring-mass-damper system provides a concise, yet rigorous, explanation for the origin of Korotkoff sounds. Fundamentally, wall stretching in expansion requires more force than wall bending in buckling. At cuff pressures between systolic and diastolic arterial pressure, audible vibrations (> 40 Hz) occur during early expansion of the artery wall beyond its zero pressure radius after the outward moving mass of tissue experiences sudden deceleration, caused by the discontinuity in stiffness between bucked and expanded states. The idealized spring-mass-damper model faithfully reproduces the time-domain waveforms of actual Korotkoff sounds in humans. Appearance of arterial sounds occurs at or just above the level of systolic pressure. Disappearance of arterial sounds occurs at or just above the level of diastolic pressure. Muffling of the sounds is explained by increased resistance of the artery to collapse, caused by downstream venous engorgement. A simple analytical model can define the physical origin of Korotkoff sounds, suggesting improved mechanical or electronic filters for their selective detection and confirming the disappearance of the Korotkoff sounds as the optimal diastolic end point.
منابع مشابه
Reintroduction of Riva-Rocci measurements to determine systolic blood pressure?
INTRODUCTION In 1896, Riva-Rocci introduced the upper arm cuff to measure systolic blood pressure. In 1905, Nicolai Sergeivich Korotkoff added the auscultatory technique, allowing measurement of both systolic and diastolic blood pressure. Both methods have, to our knowledge, never been formally tested against each other. In this study, we want to fill this gap in history. METHODS We measured ...
متن کاملABC of hypertension. Blood pressure measurement. Part I-sphygmomanometry: factors common to all techniques.
Most devices for measuring blood pressure are dependent on one common feature, namely, occluding the artery of an extremity (arm, wrist, finger, or leg) with an inflatable cuff to measure blood pressure either oscillometrically, or by detection of Korotkoff sounds. Other techniques, which are not dependent on limb occlusion, such as pulse-waveform analysis, can also be used, but these have litt...
متن کاملSystolic peak foot-to-apex time interval, a novel oscillometric technique for systolic blood pressure measurement
BACKGROUND Noninvasive blood pressure (BP) measurement is essential for the study of human physiology but automatic oscillometric devices only estimate SBP and DBP using various, undisclosed algorithms, precluding standardization and interchangeability. We propose a novel approach by tracking, during pneumatic cuff deflation, the time interval from the foot to the apex of the systolic peak of t...
متن کاملDynamic reactions produced by deflating a blood pressure cuff.
Intra-arterial pressure was recorded at various points in the compressed segment of brachial artery during deflation of a standard blood pressure cuff in human subjects with arms of normal girth. Cuff pressure and the Korotkoff sounds also were recorded simultaneously. The data were analyzed in terms of the various dynamic reactions produced by cuff deflation, which may influence the auscultato...
متن کاملA pilot application of Korotkoff sound delay time in evaluating cardiovascular status.
BACKGROUND Korotkoff sounds have been used to measure systolic and diastolic arterial blood pressures noninvasively for over 100 years. However, most of the research concerning the Korotkoff sound were focused on the origin and frequency component analyzing the Korotkoff sound signal. OBJECTIVE To show that the occurrence time of the Korotkoff sounds for each cardiac cycle demonstrates a char...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Society of Hypertension : JASH
دوره 9 12 شماره
صفحات -
تاریخ انتشار 2015