State-of-the art comparability of corrected emission spectra. 2. Field laboratory assessment of calibration performance using spectral fluorescence standards.

نویسندگان

  • Ute Resch-Genger
  • Wolfram Bremser
  • Dietmar Pfeifer
  • Monika Spieles
  • Angelika Hoffmann
  • Paul C DeRose
  • Joanne C Zwinkels
  • François Gauthier
  • Bernd Ebert
  • R Dieter Taubert
  • Jan Voigt
  • Jörg Hollandt
  • Rainer Macdonald
چکیده

In the second part of this two-part series on the state-of-the-art comparability of corrected emission spectra, we have extended this assessment to the broader community of fluorescence spectroscopists by involving 12 field laboratories that were randomly selected on the basis of their fluorescence measuring equipment. These laboratories performed a reference material (RM)-based fluorometer calibration with commercially available spectral fluorescence standards following a standard operating procedure that involved routine measurement conditions and the data evaluation software LINKCORR developed and provided by the Federal Institute for Materials Research and Testing (BAM). This instrument-specific emission correction curve was subsequently used for the determination of the corrected emission spectra of three test dyes, X, QS, and Y, revealing an average accuracy of 6.8% for the corrected emission spectra. This compares well with the relative standard uncertainties of 4.2% for physical standard-based spectral corrections demonstrated in the first part of this study (previous paper in this issue) involving an international group of four expert laboratories. The excellent comparability of the measurements of the field laboratories also demonstrates the effectiveness of RM-based correction procedures.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simple Tool for the Standardisation of Confocal Spectral Imaging Systems

Spectral fluorescence standards like dyes C-E with known corrected, i.e., instrument-independent broad and unstructured emission spectra (Ic(λem)) that present chemical equivalents of calibration lamps, are simple tools for the determination of the relative spectral responsivity or sensitivity (s(λem)) of the emission channel of fluorescence instruments under application-relevant conditions [2]...

متن کامل

Coupling Second-Order Excitation-Emission Spectrofluorimetric Data with Standard Addition method to Quantify Carvedilol in Real Samples

Prediction using pure standards is expected to be biased whenever the slope of the calibration is affected by the presence of sample matrix. Moreover, in the presence of unknown spectral interferents, first-order algorithms like partial least squares cannot be used. In this study, a method for determination of carvedilol (CAR) in tablet and urine samples is proposed by excitation-emission fluor...

متن کامل

Evaluating the effect of using different reference spectra on SAM classification results: an implication for hydrothermal alteration mapping

This research was performed with the objective of evaluating the accuracy of spectral angle mapper (SAM) classification using different reference spectra. The Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) digital images were applied in the SAM classification in order to map the distribution of hydrothermally altered rocks in the Kerman Cenozoic magmatic arc (KCMA), Iran...

متن کامل

Spectral Separation of Quantum Dots within Tissue Equivalent Phantom Using Linear Unmixing Methods in Multispectral Fluorescence Reflectance Imaging

Introduction Non-invasive Fluorescent Reflectance Imaging (FRI) is used for accessing physiological and molecular processes in biological media. The aim of this article is to separate the overlapping emission spectra of quantum dots within tissue-equivalent phantom using SVD, Jacobi SVD, and NMF methods in the FRI mode. Materials and Methods In this article, a tissue-like phantom and an optical...

متن کامل

Application of Spectral Analysis in Mapping Hydrothermal Alteration of the Northwestern Part of the Kerman Cenozoic Magmatic Arc, Iran

The northwestern part of the Kerman Cenozoic magmatic arc (KCMA) contains many areas with porphyry copper mineralization. In this research, we used the advanced space-borne thermal emission and reflection radiometer (ASTER) and Enhanced Thematic Mapper plus (ETM+) images of this region to map the distribution of hydrothermally altered rocks, based on their mineral assemblages. The spectral meas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 84 9  شماره 

صفحات  -

تاریخ انتشار 2012