Impedance of Inverter Front-ends at the Frequency of Ripple-control Signals
نویسندگان
چکیده
Ripple control is the technique of controlling loads and other devices in the distribution grid by sending lowfrequency signals along the phase conductors or the neutral conductor. The magnitude of the signal is determined by the impedance of the network, loads, capacitor banks, filters and generators. An increase of the amount of electrical equipment connected to the grid, e.g. due to an increasing use of distributed generation, changes the impedance of the power system. This can cause excessive amplification or attenuation of the control signals, resulting in the malfunction of receivers and other equipment. In this paper, the impedance of three-phase inverter front-ends at the frequency of the control signals is discussed. The following elements are taken into account: The AC filter, the switching of the inverter and the DC circuit. Equivalent impedances are calculated, which can be used in analytical calculations.
منابع مشابه
Different Types of PWM Techniques analysis for Z-Source Inverter
Abstract: This paper presents a recent popular power inverter which is impedance source or Z-source inverter (ZSI) and the comparison and analysis of two conventional PWM techniques of Z-source inverter. Due to the impedance network it couples inverter main circuit to the power source thus providing special features that can overcome the limitations of traditional voltage source inverter (VSI) ...
متن کاملREDUCTION OF INVERTER OUTPUT CURRENT RIPPLE IN CONNECTION OF FUEL CELL TO THE POWER NETWORK
In this paper, a method is introduced which reduces the harmonicdistortion of the inverter output current, connecting the fuelcell to the AC load. Using FUZZY LOGIC-PI (FLPI), the controllingmethod is engaged in optimum tuning of the PI controllercoefficients of this converter. This converter has only one DC-ACboost inverter and simultaneously has the task of increasingvoltage level and generat...
متن کاملGrid Impedance Estimation Using Several Short-Term Low Power Signal Injections
In this paper, a signal processing method is proposed to estimate the low and high-frequency impedances of power systems using several short-term low power signal injections for a frequency range of 0-150 kHz. This frequency range is very important, and thusso it is considered in the analysis of power quality issues of smart grids. The impedance estimation is used in many power system applicati...
متن کاملControl of Inverter-Interfaced Distributed Generation Units for Voltage and Current Harmonics Compensation in Grid-Connected Microgrids
In this paper, a new approach is proposed for voltage and current harmonics compensation in grid-connected microgrids (MGs). If sensitive loads are connected to the point of common coupling (PCC), compensation is carried out in order to reduce PCC voltage harmonics. In absence of sensitive loads at PCC, current harmonics compensation scenario is selected in order to avoid excessive injection of...
متن کاملImplementation and Critical Investigation on Modulation Schemes of Three Phase Impedance Source Inverter
New control circuits and algorithms are frequently proposed to control the impedance (Z) source inverter in efficient way with added benefits. As a result, several modified control techniques have been proposed in recent years. Although these techniques are clearly superior to the simple boost control method which was initially proposed along with the Z-source inverter (ZSI), little or conf...
متن کامل