Comparison of sampler filling times among selected arterial blood samplers.

نویسندگان

  • Christine N McMillen
  • Stephen Adu-Yeboah
  • Elisabeth Kagarise
  • Rebecca L Morton
  • Basak Yuce
  • F Herbert Douce
چکیده

BACKGROUND True arterial blood samples are essential in making clinical decisions for respiratory patients. Previous studies using only the Portex Pro-Vent arterial sampler have shown a significant difference between arterial and venous filling times. The goal of this study was to determine whether there is a statistically significant difference between sampler filling times measured at a normal mean arterial pressure among multiple arterial samplers with plungers and to determine whether there is a statistically significant difference in filling times between venous and normal mean arterial pressures for a sampler without a plunger. METHODS We assembled an extracorporeal laboratory model to circulate a synthetic compound composed of 0.9% sodium chloride solution and Life/form artificial blood, and we used hemostats to create pressures within the circuit. We randomly selected samplers and measured the filling times of 4 arterial samplers with plungers at a normal mean arterial pressure (93 ± 1 mm Hg). We also measured the filling time of one arterial sampler without a plunger at a normal mean arterial pressure and at a simulated venous pressure (9 ± 2 mm Hg). We used the Kruskal-Wallis one-way analysis of variance to compare arterial filling times in samplers, and we used a t test for independent samples to compare venous and arterial filling times in the sampler without a plunger. RESULTS There was a statistically significant difference between sampler filling times among the 4 arterial samplers with a plunger (P < .001). There was a statistically significant difference between arterial and venous pressure filling times for the sampler without a plunger (P < .001). CONCLUSIONS Although there was a statistically significant difference between arterial filling times among various samplers with plungers, the difference was < 1 s and was not deemed clinically important. Regardless of the sampler brand being used, respiratory therapists and other clinicians performing arterial punctures can use sampler filling time to identify a successful arterial puncture while drawing blood.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of mean arterial pressure and needle size on arterial sampler filling time.

BACKGROUND Arterial blood sampling is subject to numerous pre-analytical errors, one of which is inadvertent venous blood sampling. Especially when assessing oxygenation and titrating ventilation, accidental venous blood sampling may lead to inappropriate respiratory care and repeated percutaneous punctures. OBJECTIVE To determine the effects of mean systemic blood pressure and needle size on...

متن کامل

The effects of abnormal blood pressure on arterial sampler filling times.

BACKGROUND Sampler filling time begins with the initial flash of blood in the needle hub until the preset sampler volume is obtained. Previous studies have shown statistically significant differences between arterial and venous sampler filling times, but included only a few subjects with abnormal blood pressures. OBJECTIVE To determine whether the time required to fill a vented arterial sampl...

متن کامل

Arterial sampler filling time during arterial and venous punctures, and its relationship with mean arterial pressure in human subjects.

BACKGROUND When obtaining an arterial blood sample via percutaneous puncture, there is a risk of accidentally obtaining venous blood. Conventional methods of confirming arterial blood at the bedside, such as blood color and pulsatile return, can be misleading in patients with low blood pressure or hypoxemia. OBJECTIVE To determine if the arterial sampler filling time can be an accurate indic...

متن کامل

Site comparison of selected aerosol samplers in the wood industry.

Several samplers (IOM, CIP 10-I v1, ACCU-CAP, and Button) were evaluated at various wood industry companies using the CALTOOL system. The results obtained show that compared to the CALTOOL mouth, which can be considered to be representative of the exposure of a person placed at the same location under the same experimental conditions, the concentrations measured by the IOM, CIP 10-I v1, and ACC...

متن کامل

Comparison of the Results of Studies of Air Pollution Fungi Using the SAS Super 100, MAS 100, and Air IDEAL

Although several air sampling devices for identifying and enumerating airborne microorganisms are commercially available, each poses some limitations. The aim of this study was to evaluate air pollution fungi using three such samplers: SAS Super 100, Microbiological Air Sampler (MAS) 100, and Air IDEAL. Mycological air was taken from the cellars of a 17th-century church in Siemiatycze, Poland, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 60 4  شماره 

صفحات  -

تاریخ انتشار 2015