A Barely Alive Memory Servers: Keeping Data Active in a Low-Power State

نویسندگان

  • VLASIA ANAGNOSTOPOULOU
  • SUSMIT BISWAS
  • HEBA SAADELDEEN
  • ALAN SAVAGE
  • RICARDO BIANCHINI
  • TAO YANG
  • DIANA FRANKLIN
  • FREDERIC T. CHONG
چکیده

Current resource provisioning schemes in Internet services leave servers less than 50% utilized almost all the time. At this level of utilization, the servers’ energy efficiency is substantially lower than at peak utilization. A solution to this problem could be dynamically consolidating workloads into fewer servers and turning others off. However, services typically resist doing so, because of high response times during reactivation in handling traffic spikes. Moreover, services often want the memory and/or storage of all servers to be readily available at all times. In this paper, we propose a family of barely-alive active low-power server states that facilitates both fast re-activation and access to memory while in a low-power state. We compare these states to previously proposed active and idle states. In particular, we investigate the impact of load bursts in each energy-saving scheme. We also evaluate the additional benefits of memory access under low-power states with a study of a search service using a cooperative main-memory cache. Finally, we propose a system that combines a barelyalive state with the off state. We find that the barely-alive states can reduce service energy consumption by up to 38%, compared to an energy-oblivious system. We also find that these energy savings are consistent across a large parameter space.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Barely Alive Servers: Greener Datacenters Through Memory-Accessible, Low-Power States

Current resource provisioning schemes in Internet services leave servers less than 50% utilized almost all the time. At this level of utilization, the servers’ energy efficiency is substantially lower than at peak utilization. A solution to this problem could be dynamically consolidating workloads into fewer servers and turning others off. However, services typically resist doing so, because of...

متن کامل

Energy Conservation in Datacenters through Cluster Memory Management and Barely-Alive Memory Servers

As a result of current resource provisioning schemes in Internet services, servers end up less than 50% utilized almost all the time. At this level of utilization, the servers’ energy efficiency is less than half their efficiency at peak utilization. A solution to this problem could be consolidating workloads into fewer servers and turning others off. However, services typically resist doing so...

متن کامل

Low Power March Memory Test Algorithm for Static Random Access Memories (TECHNICAL NOTE)

Memories are most important building blocks in many digital systems. As the Integrated Circuits requirements are growing, the test circuitry must grow as well. There is a need for more efficient test techniques with low power and high speed. Many Memory Built in Self-Test techniques have been proposed to test memories. Compared with combinational and sequential circuits memory testing utilizes ...

متن کامل

Self-optimization of Performance-per-Watt for Interleaved Memory Systems

With the increased complexity of platforms coupled with data centers’ servers sprawl, power consumption is reaching unsustainable limits. Memory is an important target for platform-level energy efficiency, where most power management techniques use multiple power state DRAM devices to transition them to low-power states when they are “sufficiently” idle. However, fully-interleaved memory in hig...

متن کامل

Markovian multiserver queues with staggered setup for data centers

Queues with setup time are extensively studied because they have application in performance evaluation of power-saving data centers. In a data center, there are a huge number of servers which consume a large amount of energy. In the current technology, an idle server still consumes about 60% of its peak processing a job. Thus, the only way to save energy is to turn off servers which are not pro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011