S100 protein and its relation to cerebral microemboli in on-pump and off-pump coronary artery bypass surgery.

نویسندگان

  • Reza Motallebzadeh
  • Robin Kanagasabay
  • Martin Bland
  • Juan Carlos Kaski
  • Marjan Jahangiri
چکیده

OBJECTIVES S100 protein has been used as a marker for cerebral injury. Studies have reported lower levels in off-pump coronary artery surgery (CABG) compared to on-pump surgery. However, most of these are flawed as S100 from extracerebral sources was included (e.g. blood from cardiotomy suckers). Microemboli (high-intensity transient signals or HITS) during CABG have been implicated as a cause of postoperative neurocognitive dysfunction. The aim of this study was to compare the number of HITS during on-pump and off-pump CABG, measure S100 accurately by excluding extracerebral sources, and assess whether any changes in S100 were related to HITS. METHODS Thirty-five patients admitted for CABG were randomised to on-pump (n=20) or off-pump (n=15) surgery. Bilateral transcranial Doppler ultrasonography was performed on the middle cerebral artery to detect HITS. S100 was measured preoperatively, at termination of bypass in on-pump surgery, at completion of anastomoses in off-pump surgery, and 48 h postoperatively. A cell saver was used instead of cardiotomy suction in the on-pump group in order to limit extracerebral contamination of the S100 assay. RESULTS The number of HITS was 2016+/-1897 during on-pump and 16+/-21 during off-pump surgery (P<0.0001). In on-pump surgery S100 increased from 0.05+/-0.03 to 0.50+/-0.28 microg/l (P<0.0001) at termination of bypass. In off-pump surgery S100 increased from 0.08+/-0.05 to 0.35+/-0.20 microg/l (P<0.0001) at completion of anastomoses. The mean intraoperative S100 in the on-pump group was 1.6 times greater compared to that in the off-pump group (95% CI 0.88-2.8; P=0.01). There was no evidence of a relationship between S100 and HITS in both groups. By 48 h S100 decreased to 0.22+/-0.14 microg/l in the on-pump and 0.21+/-0.09 microg/l in the off-pump group (P<0.0001, compared to the preoperative value). CONCLUSIONS We have demonstrated a significantly higher number of cerebral microemboli in patients undergoing on-pump compared to off-pump CABG. By limiting contamination from extracerebral sources, we have shown S100 beta levels during on-pump CABG one and a half times greater than that in off-pump, although this did not reach statistical significance. In addition, we have shown no correlation between S100 beta and the total microemboli count, possibly because of the small numbers in this study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Off-Pump Versus On-Pump Coronary Artery Bypass Graft Surgery, prospective cohort study

Introduction: Coronary artery bypass grafting is a surgical operation that bypasses atherosclerotic coronary vessels and restores blood flow to the ischemic zone of hearts. And two different conventional methods are ON-pump CABG, and Off-pump CABG.  Altogether, the efficacy and safety of these two types of surgical procedures are still under debate. In this study, we aim to com...

متن کامل

Emergency Conversion from Off Pump to Cardiopulmonary Bypass in Patients with Coronary Artery Bypass Graft Surgery

Introduction: As off pump Coronary artery bypass grafting surgery (CABG) is a developing method in coronary cardiac surgery, most surgeons are anxious about the danger of emergency crash conversion. In this observational study we tried to show the rate and outcome of conversion . Material and methods: In this descriptive study about 477 coronary off-pump CABG patients were operated in Ghaem hos...

متن کامل

A Propensity Score Analysis of Renal Dysfunction in Patients after On-Pump and Off-Pump Coronary Artery Bypass Surgery

INTRODUCTION- Cardiovascular disease has emerged as a major health burden worldwide with coronary artery disease [CAD] causing highest mortality and morbidity. Coronary revascularization is the preferred treatment for patients with multivessel CAD. Based on the application of cardiopulmonary bypass [CPB], Coronary revascularization can be on-pump [OPCAB] or off-pump [CABG].The CPB is known to h...

متن کامل

Comparison of Unstable Hemodynamic Patients Undergoing Coronary Artery Bypass Graft Surgery with on- or off-Pump Methods

Introduction: Coronary artery disease (CAD) is the most common type of heart disease, with a mortality rate of 385,000 person per year in the United States. There are two main methods for CAD treatments: angioplasty and bypass surgery. Coronary Artery Bypass Grafting (CABG) is one of the greatest surgical operations of the 20th century and it is presented as most effective and long-term therapi...

متن کامل

Avoidance of Dialysis in an End-Stage Renal Disease Patient Status-post Off-pump Coronary Artery Bypass Grafting

Certain benefits are clearly associated with the use of off-pump coronary artery bypass grafting (CABG) as compared with the on-pump CABG. The superiority is more evident in patients with multiple co morbidities including renal failure.We reviewed the medical records of a 67-year-old male with a past medical history that was significant for multiple cardiovascular diseases and new-onset end-sta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 25 3  شماره 

صفحات  -

تاریخ انتشار 2004