Unusually High Intra-abdominal Opening Pressure Confirmed by Simultaneous Gastric Pressure Measurement during Laparoscopy
نویسندگان
چکیده
A 28 year-old obese woman was scheduled for robot-assisted bilateral tubal re-anastomosis under general anesthesia and neuromuscular blockade. As part of a respiratory mechanics study, gastric pressure (Pga) was measured. At the beginning of the operation, the surgeon repeatedly inserted a Veress needle consistently measuring an unusually high opening pressure of 15 mmHg, at a time when Pga was 12.5 mmHg. Based on the elevated Pga values, we inferred that the high opening pressure was a valid intra-peritoneal pressure, rather than a sign of incorrect needle placement; therefore, the surgeon proceeded with uneventful insufflation of the peritoneal cavity. This patient exhibited an unusually high opening intra-abdominal pressure that likely reflected her high degree of central obesity. Simultaneous Pga determination proved valuable in confirming intra-peritoneal location of the tip of Veress needle and may be a viable method of corroborating high opening pressures despite safe needle positions in laparoscopic cases.
منابع مشابه
Comparison of Intra-abdominal Pressure Measurement and Physical Exam for Diagnosis of Surgery Indication in Patients with Abdominal Compartment Syndrome due to Blunt Trauma
Background & Aims: Increase in abdominal pressure can lead to the so-called intra–abdominal compartment syndrome (ACS) that is often observed during the first 24 hours after sever abdominal trauma and surgery. Measurement of the intra abdominal pressure through the bladder as a non-invasive measurement can provide a quick and accurate assessment of abdominal pressure changes. This study was per...
متن کاملCo2-Pneumoperitoneum in Laparoscopic Surgery: Pathophysiologic Effects and Clinical Significance
Background: Knowledge of the pathophysiological basis of laparoscopic procedures, in particular the impact of CO2pneumoperitoneum (PNP) on the body, can prevent onset of complications during laparoscopy. Design and Methods: Standard intra-abdominal pressure (IAP), which is used during laparoscopic surgery, is 12 to 15 mm Hg. The direct effect of CO2-pneumoperitoneum is a consequence of the mech...
متن کاملThe Increase of Intra-Abdominal Pressure Can Affect Intraocular Pressure
OBJECTIVE This study aims to explore the usage of intraocular pressure measurements as the early indicator of the increase in intra-abdominal pressure. METHODS In this prospective study, 40 patients undergoing elective surgery were included. Patients were divided into four groups of 10 patients. The control group (Group C) was not subjected to laparoscopic intervention. Laparoscopic surgery w...
متن کاملEvaluating intra-abdominal pressures in a porcine model of acute lung injury by using a wireless motility capsule
BACKGROUND Intra-vesical pressure measurement as the reference standard for assessing intra-abdominal pressures is mainly indirect and discontinuous. We therefore evaluated a motility capsule for continuous intra-abdominal pressure measurement in an animal model with a high probability for capillary leakage and intestinal edema. MATERIAL/METHODS Motility capsules were inserted into the stomac...
متن کاملModerate increase in intraabdominal pressure attenuates gastric mucosal oxygen saturation in patients undergoing laparoscopy.
BACKGROUND Perioperative disturbances of microvascular blood flow and oxygenation in the intestinal tract have been hypothesized to play an important role in development of the multiple organ dysfunction syndrome. Herein, increased intra-abdominal pressure (IAP) has been identified as a key factor in the initiation of the pathophysiologic cascade. The authors hypothesized that increasing the IA...
متن کامل