Measurement of regional cerebral blood flow with 123I-IMP using one-point venous blood sampling and causality analysis: evaluation by comparison with conventional continuous arterial blood sampling.

نویسندگان

  • Hiroaki Mimura
  • Teruki Sone
  • Yoshitake Takahashi
  • Katsunori Yoshioka
  • Kenya Murase
  • Hiroshi Matsuda
  • Tatsushi Tomomitsu
  • Masao Fukunaga
چکیده

OBJECTIVE Arterial input function represents the delivery of intravascular tracer to the brain. The optimal setting of this function is essential for measuring regional cerebral blood flow (rCBF) based on the microsphere model using N-isopropyl-4-[123I]iodoamphetamine (123I-IMP), in which the arterial 123I-IMP concentration (integral value) during the initial 5 min is usually applied. We developed a novel method in which the arterial 123I-IMP concentration is estimated from that in venous blood samples. METHODS Brain perfusion SPECT with 123I-IMP was performed in 110 patients with disorders of the central nervous system. A causality analysis determined the relationship between various SPECT parameters and the ratio of the octanol-extracted arterial radioactivity concentration during the first 5 min (Caoct) to the octanol-extracted venous radioactivity concentration at 27 min after an intravenous injection of 123I-IMP (Cvoct). The Caoct/Cvoct value was estimated using various SPECT parameters and compared with the directly measured value. RESULTS The measured and estimated values of Caoct/ Cvoct (r = 0.856, n = 50) closely correlated when the following 7 parameters were included in the regression formula: radioactivity concentration in venous blood sampled at 27 min (Cv), Cvoct, Cvoct/Cv, and 4 parameters related to cerebral tissue accumulation that were measured using a four-head gamma camera 5 and 28 min after 123I-IMP injection. Furthermore, the rCBF values obtained using the input function estimated by this method also closely correlated with the rCBF values measured using the continuous arterial blood sampling (r = 0.912, n = 180). CONCLUSION These results suggest that this method would serve as a convenient and less invasive method of rCBF measurement in the clinical setting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparative study of simple methods to measure regional cerebral blood flow using iodine-123-IMP SPECT.

UNLABELLED The aim of this study was to compare the accuracy and reliability of simple methods of quantifying regional cerebral blood flow (rCBF) with 123I-labeled N-isopropyl-p-iodoamphetamine (IMP) and SPECT and to determine which method was best. METHODS Four methods were examined: (a) the microsphere method with continuous withdrawal of arterial blood, which was based on a microsphere mod...

متن کامل

[Measurements of cerebral blood flow by the noninvasive microsphere method with 123I-IMP and fan beam collimator: comparison with the continuous arterial blood sampling method].

PURPOSE AND METHODS The noninvasive microsphere (NIMS) method quantifies cerebral blood flow with N-isopropyl-p-[123I]-iodoamphetamine (123I-IMP) without blood sampling of a patient, but when a fan beam collimator is used for collecting raw data in single photon emission computed tomography (SPECT), the procedure is complicated because we have to change the collimator. In phantom and clinical s...

متن کامل

A simple non-invasive I-123-IMP autoradiography method developed by modifying the simple non-invasive I-123-IMP microsphere method

Objective: We developed a simple non-invasive I-123-N-isopropyl-p-iodoamphetamine (123I-IMP) quantification method by analyzing chest RI-angiography and single photon emission computed tomography (SPECT) images based on the microsphere model (SIMS method). Theoretically, the SIMS method could be changed to the simple non-invasive ARG (SIARG) method by modifying the integrated washout ratio (WR)...

متن کامل

A simplified double-injection method to quantify cerebral blood flow and vascular reserve using iodine-123 IMP-SPECT.

UNLABELLED We developed and evaluated a simplified double-injection method for iodine-123 N-isopropyl-p-iodoamphetamine (IMP) to quantify regional cerebral blood flow (rCBF) twice in a single SPECT session. The method enabled rapid calculations of rCBF with five 10-minute SPECT scans, a fixed distribution volume (Vd), and one-point arterial blood sampling to calibrate a standard input function ...

متن کامل

Noninvasive quantification of cerebral metabolic rate for glucose in rats using 18F-FDG PET and standard input function

Measurement of arterial input function (AIF) for quantitative positron emission tomography (PET) studies is technically challenging. The present study aimed to develop a method based on a standard arterial input function (SIF) to estimate input function without blood sampling. We performed (18)F-fluolodeoxyglucose studies accompanied by continuous blood sampling for measurement of AIF in 11 rat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 20 9  شماره 

صفحات  -

تاریخ انتشار 2006