Optimization study of suitable pre-reduction agents for selenium analysis in tomato samples by flow injection-hydride generation atomic absorption spectrometry

ثبت نشده
چکیده

The pre-reducing agents for Se speciation analysis were subject to optimize under the online reduction conditions of flow injection-hydride generation atomic absorption spectrometry using 2 M HCl as a carrier solution and 0.3% (w/v) NaBH4 in 0.2% (w/v) NaOH as a reducing agent. For total Se, the pre-reduction of Se6+to Se4+must be completed when optimizing the prereducing conditions using (i) conc. HCl, (ii) 5% (w/v) KBr/conc. HCl, (iii) 15% (w/v) KBr/ dilute HCl and (iv) 10% (w/v) thiourea/conc. HCl, under heating for 30 min to overcome their matrix effects on the calibration curve using either Se4+ or Se6+ as standard compound. From the results, all of these pre-reducing agents, except that in the presence of thiourea interfered only the calibration curve using Se4+, could be used with both Se species as expressed in terms of their conversion factors of 98-116% and 81-103% for Se4+ and Se6+, respectively. The linear range was obtained between 5-25 μg/L with 0.5 μg/L LOD and 2 μg/L LOQ. The optimal prereducing agent was applied for real tomato varieties, resulting in almost satisfactory recoveries (75.6-115.9%). The Se contents in these samples were found to be 0.07-0.10 μg/g, 0.43-0.92 μg/g and 0.50-0.99 μg/g for Se4+, Se6+ and total Se, respectively.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On-line Pre-Concentration and Separation of Inorganic Arsenic Based on Nano Platinum-Multiwall Carbon Nanotubes

On-line solid phase extraction (SPE) based on  nano adsorbent for pre-concentration of inorganic arsenic in water and waste water samples was developed prior to determine by hydride generation atomic absorption spectrometry (HG-AAS). By hydride generation simulation system (HGSS), the  inorganic arsenic in liquid samples changed to hydride form and pass through nano platinum multi wall carbon n...

متن کامل

Determination of Total Selenium in Infant Formulas: Comparison of the Performance of FIA and MCFA Flow Systems

Two flow methods, based, respectively, on flow-injection analysis (FIA) and on multicommutated flow analysis (MCFA), were compared with regard to their use for the determination of total selenium in infant formulas by hydride-generation atomic absorption spectrometry. The method based on multicommutation provided lower detection and quantification limits (0.08 and 0.27 μg L(-1) compared to 0.59...

متن کامل

Determination of low selenium concentrations by flow injection hydride generation atomic absorption spectrometry (FI-HG-AAS) - interference by perchloric acid

In routine determinations of selenium (Se) by flow injection hydride generation atomic absorption spectrometry (Fi-HG-AAS) technique a home-made equipment from commercially available components were used. An electrically heated quartz tube was used as atomiser. Blank and Se-standard solutions were analysed after wet digestion using an oxidising acid mixture (HNO3/HClO4). An absorption signal at...

متن کامل

Flow injection electrochemical hydride generation of hydrogen selenide on lead cathode: critical study of the influence of experimental parameters.

A flow injection system for the determination of selenium by electrochemical hydride generation and quartz tube atomic absorption spectrometry is described. The generator consists of an electrolytic flow-through cell with a concentric arrangement and a packed cathode made of particulated lead. The influences of sample flow rate, carrier gas flow rate and electrolysis current on the hydrogen sel...

متن کامل

Simultaneous detection of selenium by atomic fluorescence and sulfur by molecular emission by flow-injection hydride generation with on-line reduction for the determination of selenate, sulfate and sulfite.

An inductively coupled plasma atomic fluorescence spectrometry (ICP-AFS) instrument, was modified so that it was capable of monitoring transient chromatographic or flow-injection profiles and that sulfur molecular emission and selenium atomic fluorescence could be monitored simultaneously in an argon-hydrogen diffusion flame on a glass burner. The analytes were introduced as hydrogen selenide a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015