Medical radiation exposures for diagnostic radiology in Malaysia.
نویسندگان
چکیده
The medical radiation usage for diagnostic radiology in Malaysia (a Level II country) for 1990-1994 is reported, enabling a comparison to be made for the first time with the United Nations Scientific Committee on the Effects of Atomic Radiation Report. In 1994, the number of physicians, radiologists, x-ray units, and x-ray examinations per 1,000 population was 0.45, 0.005, 0.065, and 183, respectively. (Level I countries had averages of 2.6, 0.072, 0.35, and 860, respectively). In 1994, a total of 3.6 million x-ray examinations were performed; the annual effective dose per capita to the population was 0.05 mSv, and the collective effective dose was 1,000 person-Sv. Chest examinations contributed 63% of the total. Almost all examinations experienced increasing frequency from 1990 to 1994 except for barium studies, cholecystography, and intravenous urography (-23%, -36%, -51%). These decreases are related to the increasing use of ultrasound and greater availability of fiberoptic endoscopy. Notable increases during the same period were observed in computed tomography (161%), cardiac procedures (190%), and mammography (240%). In order to progress from Level II to Level I status Malaysia needs to expand and upgrade radiological service in tandem with the health care development of the country.
منابع مشابه
Local Diagnostic Reference Levels for Common Computed Tomography Procedures at a Tertiary Hospital in South Africa
Introduction: An operational computed tomography (CT) scanner is a major source of human exposure to ionizing radiation. Exposure increases the risk of cancer and aplastic anaemia. All radiation exposures should be justified and optimized to meet the clinical objective. In order to avoid the administration of excessive radiation dose to patients, diagnostic reference l...
متن کاملAssessment of the Radiation Attenuation Properties of Several Lead Free Composites by Monte Carlo Simulation
Background:In diagnostic radiology lead apron, are usually used to protect patients and radiology staff against ionizing radiation. Lead apron is a desirable shield due to high absorption and effective attenuation of x-ray photons in the diagnostic radiology range.Objective: Although lead aprons have good radiation protection properties, in recent years, researchers have been looking for altern...
متن کاملLocal Diagnostic Reference Levels for Common Pediatric X-Ray Examinations in Khorasan Razavi Province, Iran
Introduction Given the fact that children are more sensitive to radiation, compared to adults, special attention needs to be paid to radiation protection in pediatric radiology. Diagnostic reference level (DRL) has been defined to be employed as a practical tool for examining the overall performance of a radiological center in terms of patient dose among a series of similar equipments in an are...
متن کاملDose Evaluation for Common Digital Radiographic Examinations in Selected Hospitals in Pahang Malaysia
Introduction: In digital radiography, radiographers tend to increase exposure factors to acquire an acceptable image quality thereby increasing radiation dose to patients. Regarding this, the present study aimed to re-evaluate the exposure parameters and to ascertain the entrance surface dose (ESD) and effective dose (ED) of posterior-anterior (PA) chest, abdomen, and anterior-posterior (AP) l...
متن کاملMeasurement of Entrance Skin Dose and Effective Dose in The most Common Diagnostic radiology Examinations in Jiroft, Iran
Introduction: Medical uses of radiation have grown very rapidly over in the past two decades, medical uses represent the largest source of exposure to people, The most important methods in medical diagnosis are the useses of diagnostic radiology exams. Although the use of these methods is very beneficial for the treatment of patients, but ionizing radiation produces ion pairs, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Health physics
دوره 77 1 شماره
صفحات -
تاریخ انتشار 1999