A new method for determining plasma water content: application in pseudohyponatremia.
نویسندگان
چکیده
Pseudohyponatremia is a clinical condition characterized by an increased fraction of protein or lipid in plasma, thereby resulting in an artificially low plasma sodium concentration ([Na(+)](p)). Since the automated method of measuring [Na(+)](p) in most laboratories involves the use of an indirect ion-selective electrode (I-ISE), this method does not correct for elevated protein or lipid concentrations. In I-ISE, the plasma sample is diluted before the actual measurement is obtained, and the [Na(+)](p) is determined based on the assumption that plasma is normally composed of 93% plasma water. Therefore, the [Na(+)](p) as determined by I-ISE will be artificially low in clinical conditions when the plasma water content (PWC) is <93%. In contrast, the plasma is not diluted when the [Na(+)](p) is measured using direct ISE (D-ISE). This method directly measures Na(+) activity in plasma water and is therefore unaffected by the proportion of plasma occupied by water. In this study, we report a novel quantitative method for determining the PWC utilizing I-ISE and D-ISE. To validate this new method experimentally, we altered the PWC in vitro by dissolving varying amount of salt-free albumin in human plasma. We then measured PWC gravimetrically in each sample and compared the gravimetrically determined PWC with the ISE-determined PWC. Our findings indicate that the PWC can be accurately determined based on differences in the [Na(+)](p) as measured by I-ISE and D-ISE and that this new quantitative method can be a useful adjunct in the analysis of the dysnatremias.
منابع مشابه
Innovative Methodology A new method for determining plasma water content: application in pseudohyponatremia
Nguyen MK, Ornekian V, Butch AW, Kurtz I. A new method for determining plasma water content: application in pseudohyponatremia. Am J Physiol Renal Physiol 292: F1652–F1656, 2007. First published February 13, 2007; doi:10.1152/ajprenal.00493.2006.—Pseudohyponatremia is a clinical condition characterized by an increased fraction of protein or lipid in plasma, thereby resulting in an artificially ...
متن کاملRapid measurement of serum water to assess pseudohyponatremia.
Pseudohyponatremia is caused by an increased serum protein or lipid concentration producing a "space-occupying lesion" in serum water. Its presence and magnitude must be assessed in hyponatremic patients with, for example, paraproteinemia or hyperlipemic diabetic coma. In the absence of a direct-reading ion-selective electrode system, a method for measuring the water content of serum is require...
متن کاملPseudohyponatremia: Does It Matter in Current Clinical Practice?
Serum consists of water (93% of serum volume) and nonaqueous components, mainly lipids and proteins (7% of serum volume). Sodium is restricted to serum water. In states of hyperproteinemia or hyperlipidemia, there is an increased mass of the nonaqueous components of serum and a concomitant decrease in the proportion of serum composed of water. Thus, pseudohyponatremia results because the flame ...
متن کاملAssessing Relation of Soil Hydrophobicity and Soil Water Content and Determining Threshold Moisture of Organic Soil Samples
Soil water content is the most effective factor associated with the hydrophobic and hydrophilic changes in a soil. Water repellency in soils, is not a permanent feature; it can be reached in the dry season and reduced or eliminated in the wet season It can be said that in terms of moisture, there is a critical region that is defined as the threshold moisture content, where in lower moisture, th...
متن کاملDetermination of mirtazapine and desmethyl mirtazapine in human plasma by a new validated HPLC ultraviolet method with a simple and reliable extraction method: Application to therapeutic drug monitoring study by 62 real patient plasma
Determination of mirtazapine during psychopharmacotherapy in biological fluids is essential to achieve successful therapy, to avoid toxicity related to drug interactions, genetic variability and poor compliance. A new, rapid and sensitive high-performance liquid chromatography method has been developed in human plasma for the determination of mirtazapine (MRP) and N-desmethylmirtazapine (NDM) t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Renal physiology
دوره 292 5 شماره
صفحات -
تاریخ انتشار 2007