Measuring 8-250 ps short pulses using a high-speed streak camera on kilojoule, petawatt-class laser systems.

نویسندگان

  • J Qiao
  • P A Jaanimagi
  • R Boni
  • J Bromage
  • E Hill
چکیده

Short-pulse measurements using a streak camera are sensitive to space-charge broadening, which depends on the pulse duration and shape, and on the uniformity of photocathode illumination. An anamorphic-diffuser-based beam-homogenizing system and a space-charge-broadening calibration method were developed to accurately measure short pulses using an optical streak camera. This approach provides a more-uniform streak image and enables one to characterize space-charge-induced pulse-broadening effects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrafast x-ray diffraction using a streak-camera detector in averaging mode.

We demonstrate an apparatus for measuring time-dependent x-ray diffraction. X-ray pulses from a synchrotron are diffracted by a pair of Si(111) crystals and detected with an x-ray streak camera that has single-shot resolution of better than 1 ps. The streak camera is driven by a photoconductive switch, which is triggered by 100-fs laser pulses at a repetition rate of 1 kHz. The laser and the st...

متن کامل

Initial Tests of the Dual-sweep Streak Camera System Planned for Aps Particle-beam Diagnostics*

Initial tests of a dual-sweep streak system planned for use on the Advanced Photon Source (APS) have been performed using assets of the Argonne Wakefield Accelerator (AWA) facility. The short light pulses from the photoelectric injector drive laser in both the visible (-96 nm, AtI .5 ps (FWHM)), and the ultraviolet (k 248 nm, At-5 ps (FWHM)) were used. Both a W-visible S20 photocathode streak t...

متن کامل

Production of picosecond, kilojoule, and petawatt laser pulses via Raman amplification of nanosecond pulses.

Raman amplification in plasma has been promoted as a means of compressing picosecond optical laser pulses to femtosecond duration to explore the intensity frontier. Here we show for the first time that it can be used, with equal success, to compress laser pulses from nanosecond to picosecond duration. Simulations show up to 60% energy transfer from pump pulse to probe pulse, implying that multi...

متن کامل

Signal averaging x-ray streak camera with picosecond jitter

We have developed an averaging picosecond x-ray streak camera using a dc-biased photoconductive switch as a generator of a high-voltage ramp. The streak camera is operated at a sweep speed of up to 8 ps/mm, shot-to-shot jitter is less than 61 ps. The streak camera has been used to measure the time history of broadband x-ray emission from an ultrashort pulse laser-produced plasma. Accumulation o...

متن کامل

Ultrafast Magnetization Dynamics Studies using an X-ray Streak Camera

The spin dynamics of ferromagnetic thin films following an excitation by ultrashort 100-fs near-infrared laser pulses has recently received much attention. Here, a new approach is described using x-ray magnetic circular dichroism to investigate demagnetization and magnetization switching processes. In contrast to magneto-optical measurements, x-ray dichroism has the advantage of determining sep...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 84 7  شماره 

صفحات  -

تاریخ انتشار 2013