Scale and Corrosion Prevention in Cooling Water Systems Part II: Calcium Sulphate

نویسنده

  • T. Y. Soror
چکیده

This paper describes an experimental study on calcium sulphate scaling and prevention by newly treated polyacrylamide in a laboratory model. In order to study the inhibiting capacity of the chemical used, experiments were performed in solutions involving treatment of synthetic sea water with different concentrations of the polymer. Polyacrylamide gave significantly lower precipitation rate compared to the treatment in absence of inhibitor. The inhibitor probably is adsorbed on the active growth sites of the initially formed crystals. The performances of scale inhibitor with different concentrations were analyzed in terms of the amount of soluble calcium ions in solution. The results showed that the amount of scale was reduced to 0.00%, with, 10-15 ppm polymer additions, after 1 day incubation at 90°C. Antiscale agents specific to calcium sulphate deposits have recently been developed and tested on a laboratory scale. The work was also extended to study the corrosion inhibition of polyacrylamide to both C-steel and copper specimens in contact with synthetic cooling water environment. Electrochemical polarization techniques reveal that the inhibitor acts as anodic type with respect to C-steel and mixed type for copper. Corrosion current jcorr and corrosion rate CR were reduced and inhibition efficiency IE% increases with polymer additions. The inhibition effects are due to the formation of protective film. Morphological investigation for CaSO4. 2H2O gypsum crystals formed in synthetic sea water indicate reduction of calcium sulphate crystals in the presence of the polymer as indicated by scanning electron microscopic (SEM) studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Scale and Corrosion Prevention in Cooling Water Systems Part I: Calcium Carbonate

This paper presents the results of study that was undertaken to investigate the ability of a new antiscale, polyacrylamide in solving problems found in cooling water systems. The effects of the polymer on C-steel and copper dissolution in synthetic cooling water environment were studied through scale, Tafel, and Linear polarization measurements. The results obtained from this study showed that ...

متن کامل

INVESTIGATION INTO SYNERGISTIC EFFECT OF MOLYBDATE AND PHOSPHATE AS AN INHIBITOR FOR MILD STEEL CORROSION PREVENTION IN SIMULATED COOLING WATER

The synergistic behavior of molybdate and phosphate ions in mitigating the corrosion of mild steel in simulated cooling water was evaluated performing potentiodynamic polarization and impedance spectroscopy tests. Phosphate and molybdate showed a synergistic effect on corrosion inhibition of steel in simulated cooling water. The observed reduction in anodic and cathodic current densities could ...

متن کامل

Chemical Modelling of Calcium Sulphate Phase Equilibria in Multicomponent Electrolyte Solutions

A new database was developed to successfully model the solid and aqueous phase equilibria in a number of hydrometallurgical processes using the Mixed Solvent Electrolyte (MSE) model of the OLI Systems software. In order to validate the predictability of the model developed, a number of experimental measurements were conducted in multicomponent solutions containing NiSO4, H2SO4, MnSO4, HCl, etc....

متن کامل

FAILURE MECHANISMS OF REFRACTORY LININGS FOR NONFERROUS FLASH SMELTING FURNACES

Although the flash smelting technologies use different furnace designs, the refractory linings are exposed to very similar aggressive environments and, as a result, the corrosion analysis results on one type of furnace could be generally applied to other furnaces of similar high temperature processes. Particularities regarding the different chemistries of the pyrometallurgical process and opera...

متن کامل

Pilot scale evaluation of mine water (MW) as a cooling medium

Sasol One abstracts large volumes of water from various sources, such as the Zuikerbosch & Vaal River for various applications including make-up to the cooling water systems. In an attempt to evaluate the use of underground MW as an alternative cooling medium, two pilot-scale cooling towers (CTs) were used. Data of five runs (3 weeks each) at different linear flow velocities (LFVs) and cycles o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009