Stability-indicating method for simultaneous estimation of olmesartan medoxomile, amlodipine besylate and hydrochlorothiazide by RP-HPLC in tablet dosage form.

نویسندگان

  • P S Jain
  • M K Patel
  • A P Gorle
  • A J Chaudhari
  • S J Surana
چکیده

A simple, specific, accurate and precise stability-indicating reversed-phase high-performance liquid chromatographic method was developed for simultaneous estimation of olmesartan medoxomile (OLME), amlodipine besylate (AMLO) and hydrochlorothiazide (HCTZ) in tablet dosage form. The method was developed using an RP C18 base deactivated silica column (250 × 4.6 mm, 5 µm) with a mobile phase consisting of triethylamine (pH 3.0) adjusted with orthophosphoric acid (A) and acetonitrile (B), with a timed gradient program of T/%B: 0/30, 7/70, 8/30, 10/30 with a flow rate of 1.4 mL/min. Ultraviolet detection was used at 236 nm. The retention times for OLME, AMLO and HCTZ were found to be 6.72, 4.28 and 2.30, respectively. The proposed method was validated for precision, accuracy, linearity, range, robustness, ruggedness and force degradation study. The calibration curves of OLME, AMLO and HCTZ were linear over the range of 50-150, 12.5-37.5 and 31-93 µg/mL, respectively. The method was found to be sensitive. The limits of detection of OLME, AMLO and HCTZ were determined 0.19, 0.16 and 0.22 µg/mL and limits of quantification of OLME, AMLO and HCTZ were determined 0.57, 0.49 and 0.66, respectively. Forced degradation study was performed according to International Conference on Harmonization guidelines.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Stability Indicating RP-HPLC for the Simultaneous Estimation of Hydrochlorothiazide, Amlodipine Besylate and Telemisartan in Bulk and Pharmaceutical Dosage Form

A stability indicating RP-HPLC method was developed for the simultaneous estimation of the anti hypertensive drugs Hydrochlorothiazide, Amlodipine Besylate and Telemisartan. These drugs were subjected to stress studies under different conditions as per ICH guidelines. The separations were carried out using C18 reverse phase column (Agilent ODS UG 5 column, 250mm x 4.5mm,5μm) employing Acetonitr...

متن کامل

Simultaneous Estimation of Amlodipine Besylate and Olmesartan Medoxomil in Combined Tablet Dosage Form Using UV-Spectroscopy and Reverse Phase High-Performance Liquid Chromatography Method

Simple, accurate and precise ultraviolet spectrophotometric and reversed-phase high-performance liquid chromatographic (RP-HPLC) methods for simultaneous estimation of amlodipine besylate (AMLO) and olmesartan medoxomil (OLME) in combined tablet dosage form have been developed and validated. Beer’s law was obeyed in the concentration range of 5-70 and 5-60 μg/mL in methanol at 238 nm and 257 nm...

متن کامل

HPLC method development and validation for simultaneous estimation of Olmesartan Medoxomil, Hydrochlorothiazide and Amlodipine Besylate tablets

In the present work for the determination of Olmesartan Medoxomil, Hydrochlorothiazide and Amlodipine a simple, rapid and precise high performance liquid chromatography procedure has been developed and validated. The separation and quantification were achieved on a Cyano C18 column using a mobile phase of filtered and degassed mixture of buffer and acetonitrile in the ratio of 830:170 with of a...

متن کامل

SIMULTANEOUS ESTIMATION OF AMLODIPINE BESYLATE AND HYDROCHLORTHIAZIDE IN TABLET DOSAGE FORM BY RP-HPLC M.V.Kumudhavalli*, K.Anand babu, B.Jayakar

A simple, precise, rapid and accurate RP-HPLC method has been developed for the simultaneous estimation of Amlodipine besylate and Hydrochlorthiazide in tablet formulations. The chromatographic separation was achieved on a Shimadzu Symmetry C18 column (250 mm x 4.6mm, 5.0 μ particle size) using Methanol: Acetonitrile: 50mM Na2HPO4 pH7.0 (60:20:20v/v/v) with 1% triethylamine. Flow rate was 1ml/m...

متن کامل

Application of smart spectrophotometric methods and artificial neural network for the simultaneous quantitation of olmesartan medoxamil, amlodipine besylate and hydrochlorothiazide in their combined pharmaceutical dosage form

BACKGROUND New, simple and specific spectrophotometric methods and artificial neural network (ANN) were developed and validated in accordance with ICH guidelines for the simultaneous estimation of Olmesartan (OLM), Amlodipine (AML), and Hydrochlorothiazide (HCT) in commercial tablets. RESULTS For spectrophotometric methods: First, Amlodipine (AML) was determined by direct spectrophotometry at...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 50 8  شماره 

صفحات  -

تاریخ انتشار 2012