The accuracy of the Raypex5 electronic apex locator using stainless-steel hand K-file versus nickel-titanium rotary Mtwo file.
نویسندگان
چکیده
OBJECTIVES Today many clinicians use both stainless-steel hand K-files and nickel- titanium rotary files during endodontic treatment. It is of great importance for the clinician to have confidence in the accuracy of an apex locator even if these files were used interchangeably. The purpose of this in vitro study was to evaluate the accuracy of the Raypex5 electronic apex locator using stainless-steel hand K-file versus nickel-titanium rotary Mtwo file. STUDY DESIGN Twenty straight and single canals of maxillary central teeth were used. Access cavities were prepared; actual working length were determined and compared with electronic working length obtained by means of apex locator Raypex5 using stainless-steel hand K-file and nickel-titanium rotary Mtwo file. Data was analyzed by paired T-test. RESULTS There was no significant difference between 15/0.02 stainless-steel hand K- file and 10/0.04 NiTi rotary Mtwo file for the mean differences between actual and electronic working length (p=0.126). CONCLUSIONS Under the conditions of this in-vitro study, Raypex5 registered more measurements in acceptable range using 15/0.02 stainless-steel hand K- file and 10/0.04 NiTi rotary Mtwo file. It is possible to use them interchangeably without compromising the working length.
منابع مشابه
An in vivo comparison of the Root ZX II, the Apex NRG XFR, and Mini Apex Locator by using rotary nickel-titanium files.
INTRODUCTION The purpose of this study was to compare the accuracy of working length (WL) measurements by using the Root ZX II, Apex NRG XFR, and Mini Apex Locator with rotary nickel-titanium (NiTi) instruments. METHODS Twenty-eight teeth had their WLs determined with each electronic apex locator (EAL) by using 0.04 taper ProFiles sizes 40-20 in a crown-down technique until WL was reached. Fo...
متن کاملThe accuracy of the Root ZX electronic apex locator using stainless-steel and nickel-titanium files.
Numerous apex locator studies have been performed. Generally, they use only stainless-steel hand files for testing purposes. Today many clinicians use both stainless-steel and nickel-titanium files during the treatment of a case. Given the widespread use of nickel-titanium files, a comparison of the accuracy in determining length with an apex locator using stainless-steel and nickel-titanium fi...
متن کاملAn Ex-Vivo Study on the Shaping Parameters of Two Nickel-Titanium Rotary Systems Compared with Hand Instruments
UNLABELLED INTRODUCTION Rotary nickel-titanium (NiTi) instruments are thought to allow shaping of narrow, curved root canals more efficiently and more effectively than stainless steel hand instruments. However, the continued search for even more effective and safer instruments has resulted in new rotary systems being introduced on a regular basis. The aim of this study was to compare shapin...
متن کاملAn in vitro evaluation of the accuracy of four electronic apex locators using stainless-steel and nickel-titanium hand files
OBJECTIVES The purpose of this in vitro study was to evaluate the accuracy of working length (WL) determination of four electronic apex locators (EALs), namely, Root ZX (RZX), Elements diagnostic unit and apex locator (ELE), SybronEndo Mini Apex locator (MINI) and Propex pixi (PIXI) using Stainless steel (SS) and nickel-titanium (NiTi) hand files. The null hypothesis was that there was no diffe...
متن کاملIn vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination
In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination Dr. Hasheminia, S.M.* - Dr. Jafari, N.** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Abstract Background & Aim: Radiography is still the common method of measuring working length in root canal therapy. While, gag refl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medicina oral, patologia oral y cirugia bucal
دوره 15 5 شماره
صفحات -
تاریخ انتشار 2010