Potential inadequacy of automatic tube compensation to decrease inspiratory work load after at least 48 hours of endotracheal tube use in the clinical setting.

نویسندگان

  • Jun Oto
  • Hideaki Imanaka
  • Emiko Nakataki
  • Rie Ono
  • Masaji Nishimura
چکیده

BACKGROUND Endotracheal tubes (ETTs) impose a substantial respiratory work load on mechanically ventilated patients. Automatic tube compensation (ATC) should overcome this flow-dependent resistive work load; however, ETT resistance can be increased by tracheal secretions or ETT deformities. Our bench study investigated whether ATC provides effective respiratory work load relief in used ETTs. METHODS We enrolled 20 critically ill patients requiring mechanical ventilation for longer than 48 hours. After extubation, we collected the used ETTs and measured the pressure-time products (PTPs) by using a bellows-in-a-box lung model that simulated spontaneous breathing, at a respiratory rate of 10 breaths/min, inspiratory time of 1.0 s, and tidal volumes (V(T)) of 300 mL, 500 mL, and 700 mL. The ventilator was set at ATC 100% with PEEP of 5 cm H(2)O and F(IO(2)) of 0.21. The flow and airway pressure at the proximal (P(aw)) and distal (P(tr)) ends of the ETT were recorded, and the PTP integrated from P(tr) analyzed. RESULTS PTP values increased with V(T) during ATC. Even at 100% ATC the ventilator did not completely compensate for the PTP imposed by the ETT. In used ETTs, peak flow and peak P(aw) were lower and PTP values were greater than in new ETTs. As V(T) increased, the percentage difference in the PTP values between the new and used ETTs increased. CONCLUSIONS ATC does not necessarily compensate for an ETT-imposed respiratory work load. ETT configuration changes and tracheal secretions can increase ETT resistance and decrease the ability of ATC to compensate for the increased respiratory work load.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

میزان کلونیزاسیون باکتریال کانکتور لوله تراشه پس از24 ، 48 و 72ساعت استفاده مکرر در اتاق عمل

Background: Colonization of bacteria on the equipments in touch with airway and respiratory mucosa may cause respiratory infections. According to available protocols, endotracheal tube connectors should be disposable, but because of financial issues many hospitals use it more than once. In the present study, the colonization rate of endotracheal tube connectors after 24, 48 and 72 hours of admi...

متن کامل

Accuracy of automatic tube compensation in new-generation mechanical ventilators.

OBJECTIVE To compare performance of flow-adapted compensation of endotracheal tube resistance (automatic tube compensation, ATC) between the original ATC system and ATC systems incorporated in commercially available ventilators. DESIGN Bench study. SETTING University research laboratory. SUBJECTS The original ATC system, Dräger Evita 2 prototype, Dräger Evita 4, Puritan-Bennett 840. INT...

متن کامل

Automatic tube compensation: is it worthwhile?

The influence of the endotracheal tube (ETT) during weaning has been questioned. Concerns about the work of breathing (WOB) imposed by the ETT have led to the use of various corrective methods and ventilatory modes to overcome ETT resistance. Despite the theoretical advantages of different approaches, such as pressure support (PSV) and/or automatic tube compensation (ATC), no methods appear to ...

متن کامل

مقایسه اثر استفاده از ماسک حنجره (Laryngeal mask airway) و لوله کافدار حلقی (Cuffed pharyngeal tube) در بروز گلودرد پس از بیهوشی عمومی در بزرگسالان

Post-operative sore throat is one of the most common complications and complaints of patients after general anesthesia especially in operations that need endotracheal intubations. Its causes are: size of endotracheal tube and type of its cuff, inadequate airway humidification, trauma during intubation and suctioning, high flow of inspiratory gases, surgical manipulation of airway and adjacent o...

متن کامل

Effect of Gargling with Honey and Lemon Water on Cough, Sore Throat, and Hoarseness Following Endotracheal Extubation: A Clinical Trial Study

 Background and purpose: Cough, hoarseness, and sore throat are complications of intubation. The aim of this study was to evaluate the effect of gargling with honey and lemon water on cough, sore throat, and hoarseness after extubation of endotracheal tube following surgery. Materials and methods: A clinical trial was carried out in 110 patients undergoing surgery in Neyshabur 22 Bahman Hospit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 57 5  شماره 

صفحات  -

تاریخ انتشار 2012