Marginal prescription equivalent to the isocenter prescription in lung stereotactic body radiotherapy: preliminary study for Japan Clinical Oncology Group trial (JCOG1408)
نویسندگان
چکیده
A new randomized Phase III trial, the Japan Clinical Oncology Group (JCOG) 1408, which compares two dose fractionations (JCOG 0403 and JCOG 0702) for medically inoperable Stage IA NSCLC or small lung lesions clinically diagnosed as primary lung cancer, involves the introduction of a prescribed dose to the D95% of the planning target volume (PTV) using a superposition/convolution algorithm. Therefore, we must determine the prescribed dose in the D95% prescribing method to begin JCOG1408. JCOG 0702 uses density correction and the D95% prescribing method. However, JCOG 0403 uses no density correction and isocenter- prescribing method. The purpose of this study was to evaluate the prescribed dose to the D95% of the PTV equivalent to a dose of 48 Gy to the isocenter (JCOG 0403) using a superposition algorithm. The peripheral isodose line, which has the highest conformity index, and the D95% of the PTV were analyzed by considering the weighting factor, i.e. the inverse of the difference between the doses obtained using the superposition and Clarkson algorithms. The average dose at the isodose line of the highest conformity index and the D95% of the PTV were 41.5 ± 0.3 and 42.0 ± 0.3 Gy, respectively. The D95% of the PTV had a small correlation with the target volume (r2 = 0.0022) and with the distance between the scatterer and tumor volumes (r2 = 0.19). Thus, the prescribed dose of 48 Gy using the Clarkson algorithm (JCOG0403) was found to be equivalent to the prescribed dose of 42 Gy to the D95% of the PTV using the superposition algorithm.
منابع مشابه
Stereotactic Body Radiotherapy for Lung Lesions using Multiple Phase 3D-CT Based on the Analysis of Radiobiological Parameters
Introduction: Planning target volume (PTV) is generated from internal treatment volume (ITV) using four-dimensional computed tomography (4D-CT) for enhanced therapeutic gain in the stereotactic body radiotherapy for lung lesions (SBRT-Lung). This study aimed to propose a strategy to generate ITV on multiple-phase 3D-CT and enhance therapeutic gain in SBRT-Lung. <stron...
متن کاملDifference in dose‐volumetric data between the analytical anisotropic algorithm, the dose‐to‐medium, and the dose‐to‐water reporting modes of the Acuros XB for lung stereotactic body radiation therapy
The purpose of this study was to evaluate the difference in dose-volumetric data between the analytical anisotropic algorithms (AAA) and the two dose reporting modes of the Acuros XB, namely, the dose to water (AXB_Dw) and dose to medium (AXB_Dm) in lung stereotactic body radiotherapy (SBRT). Thirty-eight plans were generated using the AXB_Dm in Eclipse Treatment Planning System (TPS) and then ...
متن کاملThe evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy
Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...
متن کاملThe colossal circumvention of the lung lesion during lung stereotaxy
This is a case report on stereotaxic (Stereotactic Body Radiotherapy-SBRT) for lung cancer located in the left lower lobe (Segment 6, S6). There have been no reports on marked displacement of the peripheral lung cancer during radiotherapy. A pulmonary nodule was discovered on computed tomography (CT) conducted for a persistent cough in an 87-year-old male. According to diagnostic imaging, this ...
متن کاملAssessment of Monte Carlo algorithm for compliance with RTOG 0915 dosimetric criteria in peripheral lung cancer patients treated with stereotactic body radiotherapy
The purpose of the study was to evaluate Monte Carlo-generated dose distributions with the X-ray Voxel Monte Carlo (XVMC) algorithm in the treatment of peripheral lung cancer patients using stereotactic body radiotherapy (SBRT) with non-protocol dose-volume normalization and to assess plan outcomes utilizing RTOG 0915 dosimetric compliance criteria. The Radiation Therapy Oncology Group (RTOG) p...
متن کامل