Simultaneous Multiple Pass Steering at Jefferson Lab

نویسندگان

  • Y. Chao
  • S. A. Bogacz
  • V. A. Lebedev
  • Thomas Jefferson
چکیده

The CEBAF recirculator at Jefferson Lab includes two linear accelerators, each 200 meters in length. Due to varying betatron phase advance for different recirculation passes, misalignment, and other steering effects, orbit correction in the CEBAF linacs presents a complicated problem defying pass-by-pass solutions. Utilization of information from the beam position measurements at all recirculation passes allows us not only to perform multipass steering minimizing beam displacements inside the linacs, but also to determine displacements of linac BPM’s and focusing quadrupoles from an ideal axis. This paper describes a steering algorithm and presents the experience in multi-pass orbit correction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Beam Current Limitations in the Jefferson Lab Fel: Simulations and Analysis of Proposed Beam Breakup Experiments

A series of beam experiments is being planned in the Jefferson Lab FEL driver accelerator in order to study multi-pass beam breakup instabilities in the machine and to test the predictions of the numerical code TDBBU. The tests are extensions of previously performed or proposed experiments, and will be considerably more sensitive with the present configuration. The experiments will include: a) ...

متن کامل

Neutron Transversity at Jefferson Lab

Nucleon transversity and single transverse spin asymmetries have been the recent focus of large efforts by both theorists and experimentalists. On-going and planned experiments from HERMES, COMPASS and RHIC are mostly on the proton or the deuteron. Presented here is a planned measurement of the neutron transversity and single target spin asymmetries at Jefferson Lab in Hall A using a transverse...

متن کامل

Operative Time Directly Correlates with Blood Loss and Need for Blood Transfusion in Total Joint Arthroplasty

Background: Allogeneic blood transfusion in patients undergoing total joint arthroplasty (TJA) has been shown tonegatively affect patient outcomes. This study aimed to examine if there is a correlation between operative time and theneed for allogeneic blood transfusions during TJA.Methods: We performed a retrospective review of 866 patients who underwent primary TJA during a o...

متن کامل

Review of Alignment Activities at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (Jefferson Lab) comprises a 6 GeV continuous electron beam accelerator (CEBAF) delivering beam to three experimental halls, and a kilowatt range tunable free electron laser (FEL), currently being upgraded to a 10 kW machine. The progression into steady state experimental runs at the facility has allowed the alignment group the opportunity to in...

متن کامل

n uc l - ex / 0 10 90 04 v 1 7 S ep 2 00 1 1 Nucleon Structure in the Resonance Region ∗

I discuss recent results of inclusive and exclusive electroproduction experiments at Jefferson Lab. They include measurements of the spin response for protons and neutrons in the resonance region, exclusive single pion and multiple pion production to measure resonance transition multipoles, and searches for missing quark model states. A brief outlook to the new domain of Generalized Parton Dist...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999