Quantification of microcirculatory parameters by joint analysis of flow‐compensated and non‐flow‐compensated intravoxel incoherent motion (IVIM) data

نویسندگان

  • André Ahlgren
  • Linda Knutsson
  • Ronnie Wirestam
  • Markus Nilsson
  • Freddy Ståhlberg
  • Daniel Topgaard
  • Samo Lasič
چکیده

The aim of this study was to improve the accuracy and precision of perfusion fraction and blood velocity dispersion estimates in intravoxel incoherent motion (IVIM) imaging, using joint analysis of flow-compensated and non-flow-compensated motion-encoded MRI data. A double diffusion encoding sequence capable of switching between flow-compensated and non-flow-compensated encoding modes was implemented. In vivo brain data were collected in eight healthy volunteers and processed using the joint analysis. Simulations were used to compare the performance of the proposed analysis method with conventional IVIM analysis. With flow compensation, strong rephasing was observed for the in vivo data, approximately cancelling the IVIM effect. The joint analysis yielded physiologically reasonable perfusion fraction maps. Estimated perfusion fractions were 2.43 ± 0.81% in gray matter, 1.81 ± 0.90% in deep gray matter, and 1.64 ± 0.72% in white matter (mean ± SD, n = 8). Simulations showed improved accuracy and precision when using joint analysis of flow-compensated and non-flow-compensated data, compared with conventional IVIM analysis. Double diffusion encoding with flow compensation was feasible for in vivo imaging of the perfusion fraction in the brain. The strong rephasing implied that blood flowing through the cerebral microvascular system was closer to the ballistic limit than the diffusive limit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dependence of Brain Intravoxel Incoherent Motion Perfusion Parameters on the Cardiac Cycle

Measurement of microvascular perfusion with Intravoxel Incoherent Motion (IVIM) MRI is gaining interest. Yet, the physiological influences on the IVIM perfusion parameters ("pseudo-diffusion" coefficient D*, perfusion fraction f, and flow related parameter fD*) remain insufficiently characterized. In this article, we hypothesize that D* and fD*, which depend on blood speed, should vary during t...

متن کامل

Perfusion Assessment Using Intravoxel Incoherent Motion-Based Analysis of Diffusion-Weighted Magnetic Resonance Imaging: Validation Through Phantom Experiments.

OBJECTIVES The aims of this study were to demonstrate the theoretical meaning of intravoxel incoherent motion (IVIM) parameters and to compare the robustness of 2 biexponential fitting methods through magnetic resonance experiments using IVIM phantoms. MATERIALS AND METHODS Intravoxel incoherent motion imaging was performed on a 3 T magnetic resonance imaging scanner using 15 b values (0-800 ...

متن کامل

Characterization of the diffusion coefficient of blood

PURPOSE To characterize the diffusion coefficient of human blood for accurate results in intravoxel incoherent motion imaging. METHODS Diffusion-weighted MRI of blood samples from 10 healthy volunteers was acquired with a single-shot echo-planar-imaging sequence at body temperature. Effects of gradient profile (monopolar or flow-compensated), diffusion time (40-100 ms), and echo time (60-200 ...

متن کامل

Bayesian intravoxel incoherent motion parameter mapping in the human heart

BACKGROUND Intravoxel incoherent motion (IVIM) imaging of diffusion and perfusion in the heart suffers from high parameter estimation error. The purpose of this work is to improve cardiac IVIM parameter mapping using Bayesian inference. METHODS A second-order motion-compensated diffusion weighted spin-echo sequence with navigator-based slice tracking was implemented to collect cardiac IVIM da...

متن کامل

Combined intravoxel incoherent motion and diffusion tensor imaging of renal diffusion and flow anisotropy.

PURPOSE We used a combined intravoxel incoherent motion-diffusion tensor imaging (IVIM-DTI) methodology to distinguish structural from flow effects on renal diffusion anisotropy. METHODS Eight volunteers were examined with IVIM-DTI at 3T with 20 diffusion directions and 10 b-values. Mean diffusivity (MD) and fractional anisotropy (FA) from DTI analysis were calculated for low (b ≤ 200 s/mm(2)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 29  شماره 

صفحات  -

تاریخ انتشار 2016