The effect of local and systemic application of tranexamic acid on the amount of blood loss and allogeneic blood transfusion after total knee replacement.
نویسندگان
چکیده
The effect of local and systemic Tranexamic Acid on blood loss and need for transfusion after total knee replacement was compared prospectively. Between 2012-2013, 90 patients with unilateral TKR were included. They were randomly divided into 3 and 15 mg/kg TXA was infused before and 10 mg/kg 1 hour after surgery in Group 1, 2 gr TXA was used topically in 2 and no TXA was applied in 3. Total blood loss and transfusion rate were used as outcome. Mean amounts of blood loss were 898.03 ± 298.21, 823.64 ± 224.33 and 1263.77 ± 298.79 ml in Groups 1, 2 and 3 respectively. There was a decrease in blood loss in TXA groups (p < 0.001). No difference was found between local and systemic groups (p = 0.385). Transfusion was not required in TXA groups but it was 8 in control group. No thromboembolic problem was seen in any patient. Since TXA decreased blood loss and lessen the need for transfusion significantly without increasing thromboembolic events in TKR, we suggest its usage in TKR either systemically or topically whenever possible. Level of evidence: Prospective Randomized Controlled Trial, Level II).
منابع مشابه
Tranexamic Acid in Total Joint Arthroplasty: Efficacy and Safety
Despite improvements in surgical and anesthetic techniques, total joint arthroplasty (TJA) is still associated with substantial blood loss and postoperative anemia (1). A considerable portion of patients with postoperative anemia require blood transfusion, which has been shown to negatively affect the outcome of TJA and predisposes patients to development of surgical site infection and peripr...
متن کاملWhich Route of Tranexamic Acid Administration is More Effective to Reduce Blood Loss Following Total Knee Arthroplasty?
Background: The most appropriate route of tranexamic acid administration is controversial. In the current study, we compared the efficacy of intravenous (IV) and topical intra-articular tranexamic acid in reducing blood loss and transfusion rate in patients who underwent primary total knee arthroplasty. Methods: One hundred twenty 120 patients were scheduled to undergo primary total knee arth...
متن کاملIntraarticular Administration of Tranexamic Acid Following Total Knee Arthroplasty: A Case-control Study
Background: Tranexamic acid (TXA) has received extensive attention in management of blood loss in orthopedic surgeries. However, the ideal method of TXA administration is still controversial. This study aims to determine whether intraarticular injection of TXA reduces blood loss after total knee arthroplasty (TKA). Methods: Through a retrospective case-control study consecutive TKA patients...
متن کاملThe Efficacy of Intravenous Versus Topical Use of Tranexamic Acid in Reducing Blood Loss after Primary Total Knee Arthroplasty: A Randomized Clinical Trial
Background: Blood loss during and immediately after total knee arthroplasty (TKA) is among the most challenging concerns. It has been demonstrated that Tranexamic acid (TXA) can help to reduce perioperative blood loss. TXA can be used as an oral, topical or intravenous injection. Many studies evaluated the effectiveness of each route of administration but few works on a comparison between them....
متن کاملIntra-articular versus Intravenous Tranexamic Acid in Total Knee Arthroplasty: A Randomized Clinical Trial
Background: Total knee arthroplasty (TKA) can cause excessive blood loss requiring allogenic transfusions.Tranexamic acid (TXA) has been increasingly used for lowering blood loss. The present study aimed to comparethe efficacy of intravenous (IV) and intra-articular (IA) administrations of TXA in TKA patients who receive aspirin aschemoprophylaxis and uses no drain post-operat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Acta orthopaedica Belgica
دوره 81 4 شماره
صفحات -
تاریخ انتشار 2015