Real-Time Gating of IVUS Sequences Based on Motion Blur Analysis: Method and Quantitative Validation

نویسندگان

  • Carlo Gatta
  • Simone Balocco
  • Francesco Ciompi
  • Rayyan Hemetsberger
  • Oriol Rodriguez-Leor
  • Petia Radeva
چکیده

Intravascular Ultrasound (IVUS) is an image-guiding technique for cardiovascular diagnostic, providing cross-sectional images of vessels. During the acquisition, the catheter is pulled back (pullback) at a constant speed in order to acquire spatially subsequent images of the artery. However, during this procedure, the heart twist produces a swinging fluctuation of the probe position along the vessel axis. In this paper we propose a real-time gating algorithm based on the analysis of motion blur variations during the IVUS sequence. Quantitative tests performed on an in-vitro ground truth data base shown that our method is superior to state of the art algorithms both in computational speed and accuracy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modelling of image-catheter motion for 3-D IVUS

Three-dimensional intravascular ultrasound (IVUS) allows to visualize and obtain volumetric measurements of coronary lesions through an exploration of the cross sections and longitudinal views of arteries. However, the visualization and subsequent morpho-geometric measurements in IVUS longitudinal cuts are subject to distortion caused by periodic image/vessel motion around the IVUS catheter. Us...

متن کامل

Image-Based Frame Gating for Contrast-Enhanced IVUS Sequences

Numerous recent reports have noted the potential uses of contrast imaging in intravascular ultrasound (IVUS). In IVUS contrast studies, a particular region-of-interest in the vessel wall or surrounding tissues is monitored over time in order to assess the perfusion of a contrast agent introduced during imaging. However, as this procedure is often carried out in the coronary arteries, the result...

متن کامل

Manifold Learning for Image-Based Gating of Intravascular Ultrasound(IVUS) Pullback Sequences

Intravascular Ultrasound(IVUS) is an imaging technology which provides cross-sectional images of internal coronary vessel structures. The IVUS frames are acquired by pulling the catheter back with a motor running at a constant speed. However, during the pullback, some artifacts occur due to the beating heart. These artifacts cause inaccurate measurements for total vessel and lumen volume and li...

متن کامل

Advanced Motion Correction Methods in PET

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

متن کامل

A quantitative investigation on lung tumor site on its motion tracking in radiotherapy with external surrogates

Introduction: In external beam radiotherapy each effort is done to deliver 3D dose distribution onto the tumor volume uniformly, while minimizing the dose to healthy organs at the same time. Radiation treatment of tumors located at thorax region such as lung and liver has a challenging issue during target localization since these tumors move mainly due to respiration. There are...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention

دوره 13 Pt 2  شماره 

صفحات  -

تاریخ انتشار 2010