Successful 1:1 proportion ventilation with a unique device for independent lung ventilation using a double-lumen tube without complications in the supine and lateral decubitus positions. A pilot study
نویسندگان
چکیده
INTRODUCTION Adequate blood oxygenation and ventilation/perfusion matching should be main goal of anaesthetic and intensive care management. At present, one of the methods of improving gas exchange restricted by ventilation/perfusion mismatching is independent ventilation with two ventilators. Recently, however, a unique device has been developed, enabling ventilation of independent lungs in 1:1, 2:1, 3:1, and 5:1 proportions. The main goal of the study was to evaluate the device's utility, precision and impact on pulmonary mechanics. Secondly- to measure the gas distribution in supine and lateral decubitus position. MATERIALS AND METHODS 69 patients who underwent elective thoracic surgery were eligible for the study. During general anaesthesia, after double lumen tube intubation, the aforementioned control system was placed between the anaesthetic machine and the patient. In the supine and lateral decubitus (left/right) positions, measurements of conventional and independent (1:1 proportion) ventilation were performed separately for each lung, including the following: tidal volume, peak pressure and dynamic compliance. RESULTS Our results show that conventional ventilation using Robertshaw tube in the supine position directs 47% of the tidal volume to the left lung and 53% to the right lung. Furthermore, in the left lateral position, 44% is directed to the dependent lung and 56% to the non-dependent lung. In the right lateral position, 49% is directed to the dependent lung and 51% to the non-dependent lung. The control system positively affected non-dependent and dependent lung ventilation by delivering equal tidal volumes into both lungs with no adverse effects, regardless of patient's position. CONCLUSIONS We report that gas distribution is uneven during conventional ventilation using Robertshaw tube in the supine and lateral decubitus positions. However, this recently released control system enables precise and safe independent ventilation in the supine and the left and right lateral decubitus positions.
منابع مشابه
Double-lumen endotracheal tube for one-lung ventilation through a fresh tracheostomy stoma: a case report.
For one-lung ventilation in many surgical cases, double-lumen endotracheal tubes are the first-line choice for airway management. For most cases, double-lumen endotracheal tubes are faster, easier to place, cheaper, and less prone to malposition than today's bronchial blocker devices. This report describes an elective tracheostomy and the use of a double-lumen endotracheal tube directly through...
متن کاملVideo-assisted thoracic surgery for superior posterior mediastinal neurogenic tumour in the supine position
Video-assisted thoracic surgery (VATS) for a superior posterior mediastinal lesion is routinely done in the lateral decubitus position similar to a standard thoracotomy using a double-lumen endotracheal tube for one-lung ventilation. This is an area above the level of the pericardium, with the superior thoracic opening as its superior limit and its inferior limit at the plane from the sternal a...
متن کاملTHE EFFECT OF CHANGE IN POSITION ON INTRATRACHEAL CUFF PRESSURE IN PATIENTS UNDERGOING SURGERY WITH GENERAL ANESTHESIA: A PROSPECTIVE ANALYTICAL STUDY
Background & Aims: Tracheal intubation with a cuffed tube for the administration of general anesthesia is routine. The cuff of the endotracheal tube is inflated with air to achieve an adequate seal to prevent aspiration and leakage of air and anesthetic gases. Whereas over-inflation can decrease the mucosal perfusion, leading to pressure necrosis and nerve palsies. This study aimed to evaluate ...
متن کاملتعیین موقعیت لولههای تراشه دابل لومن در جراحی توراکس: کمپلیانس بگ در مقایسه با برونکوسکوپ فیبراوپتیک
Background: Lung separation is the basis of thoracic anesthesia, which is performed by different instruments. Checking probable malpositioning of tracheal tube needs fiberoptic bronchoscopy. The aim of this study was to compare respirator suggested compliance with fiberoptic findings in detecting major tracheal tube malpositioning.Methods: A total of 256 patients undergoing thoracic surgery wit...
متن کاملاستفاده همزمان از دو ونتیلاتور برای درمان عوارض ریوی ناشی از تهویه مکانیکی در بیمار مولتیپل تروما: گزارش مورد
Background and Objective: Some of multiple trauma patients admitted in ICU (Intensive Care Unit) are intubated and ventilated by mechanical ventilation. These patients are prone to many complications such as lung disease. Reasons for this complication are patients without any movement, incomplete cough reflex, GI aspiration and then not a good pulmonary discharge prone the lungs of patients to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -