Measuring 3D knee dynamics using center out radial ultra-short echo time trajectories with a low cost experimental setup

نویسندگان

  • Martin Krämer
  • Karl-Heinz Herrmann
  • Heide Boeth
  • Christoph von Tycowicz
  • Christian König
  • Stefan Zachow
  • Rainald M Ehrig
  • Hans-Christian Hege
  • Georg N Duda
  • Jürgen R Reichenbach
چکیده

Measuring 3D knee dynamics using center out radial ultra-short echo time trajectories with a low cost experimental setup Martin Krämer, Karl-Heinz Herrmann, Heide Boeth, Christoph von Tycowicz, Christian König, Stefan Zachow, Rainald M Ehrig, Hans-Christian Hege, Georg N Duda, and Jürgen R Reichenbach Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena University Hospital Friedrich Schiller University Jena, Jena, Germany, Julius Wolff Institute and Center for Musculoskeletal Surgery, Charité – Universitätsmedizin Berlin, Berlin, Germany, Zuse Institute Berlin, Berlin, Germany

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast 3D UTE Imaging of Knee Connective Tissues on a Clinical 3T Scanner

INTRODUCTION Connective tissues in human knee joint, such as articular cartilage, menisci, or ligaments, have short transverse relaxation time components (T2 ~5ms) due to their collagen-rich micro-structures (1). To image those short-T2 components with minimum signal loss, special pulse sequences capable of ultra-short echo time (UTE) are desired. A number of UTE sequences have been developed i...

متن کامل

Comparison of Three-Dimensional Double-Echo Steady-State Sequence with Routine Two-Dimensional Sequence in the Depiction of Knee Cartilage

Introduction: There are some routine two-dimensional sequences, including short tau inversion recovery (STIR), T2-weighted fast-spin echo (T2W-FSE), and proton-density fast spin-echo for diagnosing osteoarthritis and lesions of the knee cartilage. However, these sequences have some disadvantages, such as long scan time, inadequate spatial resolution, and suboptimal tis...

متن کامل

Rapid 3D-Sodium MRI of Knee Joint In-vivo at 7T

Introduction Loss of glycosaminoglycans (GAG) is a signature of early osteoarthritis (OA). Although sodium MRI has been shown to correlate linearly with GAG concentration (1, 2), it poses major challenges at clinical magnetic field strengths (1.5T/3.0T) in terms of low signal-to-noise (SNR), poor spatial resolution and long acquisition times due to low natural abundance, low sodium concentratio...

متن کامل

A modified EPI sequence for high-resolution imaging at ultra-short echo time.

A robust modification of echo-planar imaging dubbed double-shot echo-planar imaging with center-out trajectories and intrinsic navigation (DEPICTING) is proposed, which permits imaging at ultra-short echo time. The k-space data is sampled by two center-out trajectories with a minimal delay achieving a temporal efficiency similar to conventional single-shot echo-planar imaging. Intersegment phas...

متن کامل

The shifted radial reordering for intermediate TE imaging in 3D long echo train acquisition

Introduction Use of nonselective pulses and modulated flip angles (aka SPACE, [2, 3, 4]) in refocusing pulses improves the sampling efficiency in 3D turbo spin echo imaging. Two flexible reordering schemes, the linear mode and the radial mode, have been proposed [1] to circumvent some intrinsic limitations of the rectangular kspace sampling grid (e.g., allowing for flexible k-space coverage) in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014