Comparison of Miller and Airtraq laryngoscopes for orotracheal intubation by physicians wearing CBRN protective equipment during infant resuscitation: a randomized crossover simulation study.
نویسندگان
چکیده
BACKGROUND The purpose of this study was to evaluate the performance of orotracheal intubation with the Miller laryngoscope compared with the Airtraq laryngoscope by emergency and pediatric physicians wearing CBRN-PPE type III on infant manikins with conventional airway. We hypothesized that in this situation, the orotracheal intubation with the Airtraq laryngoscope would be faster and more effective than with the Miller laryngoscope. METHODS This was a prospective, randomized, crossover, single-center study who recruited emergency department physicians on a voluntary basis. Each physician performed a total of 20 intubation trials while in CBRN-PPE with the two intubation techniques, Miller and Airtraq. Intubations by each airway device were tested over ten consecutive runs. The order of use of one or the other devices was randomized with a ratio of 1:1. The primary endpoint was overall orotracheal intubation success. RESULTS Fifty-five emergency and pediatric physicians were assessed for eligibility. Forty-one physicians were included in this study and 820 orotracheal intubation attempts were performed. The orotracheal intubation success rate with the Airtraq laryngoscope was higher than with the Miller (99% vs. 92%; p-adjusted <.001). The orotracheal intubation and glottis visualization times decreased with the number of attempts (p <.001). The median orotracheal intubation time with the Airtraq laryngoscope was lower than with the Miller laryngoscope (15 s vs. 20 s; p-adjusted <.001). The median glottis visualization time with the Airtraq laryngoscope and with the Miller laryngoscope were not different (6.0 s vs. 7.5 s; p-adjusted =.237). Thirty-four (83 %) physicians preferred the Airtraq laryngoscope versus 6 (15 %) for the Miller (p-adjusted <.001). DISCUSSION For tracheal intubation by physicians wearing CBRN-PPE during infant resuscitation simulation, we showed that the orotracheal intubation success rate with the Airtraq laryngoscope was higher than with the Miller laryngoscope and that orotracheal intubation time with the Airtraq laryngoscope was lower than with the Miller laryngoscope. CONCLUSIONS It seems useful to train the physicians in emergency departments in the use of pediatric Airtraq and for the management of CBRN risks.
منابع مشابه
Influence of personal protective equipment on the performance of life-saving interventions by emergency medical service personnel
Prompt live-saving interventions, such as cardiopulmonary resuscitation (CPR), intravenous cannulation (IVC), and endotracheal intubation (ETI), are important for severely injured victims of chemical, biological, radiological, and nuclear (CBRN) disasters. Interventions sometime have to be performed by emergency medical service (EMS) personnel with personal protective equipment (PPE) worn in wa...
متن کاملIntubation performance using different laryngoscopes while wearing chemical protective equipment: a manikin study
OBJECTIVES This study aimed to compare visualisation of the vocal cords and performance of intubation by anaesthetists using four different laryngoscopes while wearing full chemical protective equipment. SETTING Medical simulation center of a university hospital, department of anaesthesiology. PARTICIPANTS 42 anaesthetists (15 females and 27 males) completed the trial. The participants were...
متن کاملComparisons of the Pentax-AWS, Glidescope, and Macintosh Laryngoscopes for Intubation Performance during Mechanical Chest Compressions in Left Lateral Tilt: A Randomized Simulation Study of Maternal Cardiopulmonary Resuscitation
PURPOSE Rapid advanced airway management is important in maternal cardiopulmonary resuscitation (CPR). This study aimed to compare intubation performances among Pentax-AWS (AWS), Glidescope (GVL), and Macintosh laryngoscope (MCL) during mechanical chest compression in 15° and 30° left lateral tilt. METHODS In 19 emergency physicians, a prospective randomized crossover study was conducted to e...
متن کاملEndotracheal intubation in patients with cervical spine immobilization: a comparison of macintosh and airtraq laryngoscopes.
BACKGROUND The Airtraq laryngoscope (Prodol Ltd., Vizcaya, Spain) is a novel single-use tracheal intubation device. The authors compared ease of intubation with the Airtraq and Macintosh laryngoscopes in patients with cervical spine immobilization in a randomized, controlled clinical trial. METHODS Forty consenting patients presenting for surgery requiring tracheal intubation were randomly as...
متن کاملComparison of the Airtraq® and Truview® laryngoscopes to the Macintosh laryngoscope for use by Advanced Paramedics in easy and simulated difficult intubation in manikins
BACKGROUND Paramedics are frequently required to perform tracheal intubation, a potentially life-saving manoeuvre in severely ill patients, in the prehospital setting. However, direct laryngoscopy is often more difficult in this environment, and failed tracheal intubation constitutes an important cause of morbidity. Novel indirect laryngoscopes, such as the Airtraq and Truview laryngoscopes may...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Scandinavian journal of trauma, resuscitation and emergency medicine
دوره 24 شماره
صفحات -
تاریخ انتشار 2016